PE.L2-3.10.5
Manage Physical Access [CUI Data]
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- aphysical access devices are identified;
- bphysical access devices are controlled; and
- cphysical access devices are managed.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Know every physical access device you have (keys, badges, fobs, alarm codes, door combinations), keep them under control so only authorized people hold or can issue them, and manage them over their life: issue on approval, collect and disable at departure, rekey or change codes when something is lost. A key and badge inventory reconciled against people is the core evidence.
The minimum for a small organization · Expert CMMC's reading, not official text
List every key, badge, fob and alarm code that opens your controlled areas [a], and control [b] and manage [c] them; the usual way is to keep spares locked away and issue them only with approval, and to take them back or disable them when someone leaves, changing codes or locks as needed when one is lost.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessList every physical access device: each key, badge, fob, alarm code and combination.[a]SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.196
Quoted words
- “physical access devices are identified”
- 2Recommended wayProcessFor objective [a], record each key's stamp or serial number, what each device opens and who holds it. The guide's further discussion says physical access devices are only strong protection if you know who has them and what access they allow (L2 guide p.196), and its example checks returned keys against their serial numbers (L2 guide p.197).[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5andCMMC Assessment Guide Level 2 v2.13p.197 PE.L2-3.10.5
- 3Required outcomeProcessControl and manage those devices.[b][c]SourceCMMC Assessment Guide Level 2 v2.13objectives [b] and [c], p.196
Quoted words
- “physical access devices are controlled”
- “physical access devices are managed”
- 4Recommended wayProcessFor objectives [b] and [c], keep spares locked away, let only named people issue keys or program badges and codes, issue them only to approved holders, collect or disable them when someone leaves or changes role, change codes or locks as needed when one is lost or not returned, and keep locks and readers working. The guide's assessment considerations ask whether access to physical access devices is limited to authorized individuals and whether devices are managed, for example by revoking key card access, changing locks as needed and maintaining access control devices and systems (L2 guide p.197).[b][c]
You can tell it worked when spare keys and unassigned badges are locked away, every key or badge in use is held by an approved holder on the inventory, and those of people who have left were returned or disabled, with codes or locks changed where needed when one was not returned.
Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.197 PE.L2-3.10.5 - 5Recommended wayProcessBuild an inventory of physical access devices: each key (with stamp or serial number and the doors it opens), badge or fob (with ID number and door groups), alarm user code and combination, and who holds each one. Include spares and master keys.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
- 6Recommended wayTechnicalControl the devices: keep spare keys, unassigned badges and blank cards in a locked key cabinet; use restricted keyway locks so keys cannot be copied at a hardware store; limit who can program the badge system or alarm panel to named administrators with their own logins.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
- 7Recommended wayProcessIssue devices only with documented approval tied to the physical access authorization list; holders sign for keys and badges.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
- 8Recommended wayProcessManage changes: disable badges and collect keys the same day someone leaves (part of the offboarding checklist), update door groups when roles change, change alarm codes and combinations after departures, and rekey locks when a key is lost or not returned.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
- 9Recommended wayProcessReconcile the inventory quarterly: compare holders to the authorized list, confirm spares are in the cabinet, check the badge system for unassigned or stale cards, maintain and test the access-control hardware, and record the result.[a][b][c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Physical access device inventory[a]
Key and badge issuance records[b]
Access-control administrator list[b]
Revocation and rekey records[c]
The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
7 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- No inventory of who has keys, and keys stamped 'Do Not Duplicate' that were copied anyway.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.197 PE.L2-3.10.5
- Badges of departed staff still active because nobody told the office manager.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.197 PE.L2-3.10.5
- One shared alarm code used by everyone for years.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.196 PE.L2-3.10.5
- Badge system admin login shared or still held by the installer.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.197 PE.L2-3.10.5
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: PE.L1-b.1.ix, PE.L2-3.10.1, PE.L2-3.10.4, PS.L2-3.9.2
Editorial implementation guidance published November 20, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.10.5SP 800-171 Rev 3
03.10.0703.10.05 withdrawn; incorporated intoSP 800-53 Rev 4
PE-3SP 800-53 Rev 5
PE-3DSPE-5SHow these were reachedHide how these were reached
- PE-3 · Physical Access Control
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-3 → 800-53 Rev 5 PE-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-3NIST: 03.10.07 also: 3.10.3, 3.10.4 incorporated into
- PE-5 · Access Control for Output Devices
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-5NIST: 03.10.07 also: 3.10.3, 3.10.4 incorporated into
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (7 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- PE.L2-3.10.5 → 3.10.5“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Control and manage physical access devices.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You are a facility manager. A team member retired today and returns their company keys to you. The project on which they were working requires access to areas that contain equipment with CUI. You receive the keys, check your electronic records against the seria l numbers on the keys to ensure all have been returned, and mark each key returned [c].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Physical and environmental protection policy; procedures addressing physical access control; system security plan; physical access control logs or records; inventory records of physical access control devices; system entry and exit points; records of key and lock combination changes; storage locations for physical access control devices; physical access control devices; list of security safeguards controlling access to designated publicly accessible areas within facility; other relevant documents or records
Common mistakes
Failing to recover, revoke, inventory, or replace keys and badges as circumstances change.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/