PE.L2-3.10.1
Limit Physical Access [CUI Data]
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- aauthorized individuals allowed physical access are identified;
- bphysical access to organizational systems is limited to authorized individuals;
- cphysical access to equipment is limited to authorized individuals; and
- dphysical access to operating environments is limited to authorized individuals.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Limit physical access to the systems, equipment and spaces where CUI is handled to people you have authorized. Define the controlled areas in the SSP, keep an authorization list, issue keys or badges only to people on it, lock server and network rooms and CUI work areas, and keep printers and screens out of sight of visitors. Assessors walk the facility for this one, so what they see must match what the documents say.
The minimum for a small organization · Expert CMMC's reading, not official text
Name the people allowed into the areas where CUI systems and equipment are [a], and keep everyone else out [b] [c] [d]. For a small shop that is a short authorization list, locked or badge-controlled doors to those areas, servers and network gear in a locked room or rack, printers placed away from visitors, and a check of who holds keys or badges.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessKeep a list of the people authorized for physical access to each controlled area, issue keys, badges or codes only to them, and compare the list with who holds them whenever people join, leave or change role.[a]
You can tell it worked when the authorization list names each person and the areas they may enter.
- 2Required outcomeTechnicalKeep everyone else out: lock, badge-control or staff the doors to the areas where CUI systems and equipment are, keep servers and network gear in a locked room or rack or another secured area, and place printers and screens so their output is not exposed to people who are not authorized.[b][c][d]
You can tell it worked when the people holding keys or badges to the controlled areas match the authorization list, and printers that output CUI sit inside a controlled area or release output only to an authorized person at the device.
- 3
- 4Recommended wayProcessMaintain an authorization list per controlled area: person, role, area, credential, approval date and approver. Grant access only after approval and remove it the same day someone leaves or changes role.[a]
- 5Recommended wayTechnicalProtect the operating environment: lock or badge-control entrances to CUI areas, separate them from public areas and shared building space, and keep doors closed and locked when unattended. Use card readers, electronic locks or restricted-keyway locks depending on size and budget.[b][d]
- 6Recommended wayTechnicalProtect systems and equipment: servers, firewalls, switches and NAS in a locked room or locked rack; CUI workstations in controlled areas; port and cable locks for equipment in shared spaces; printers and copiers that output CUI in a controlled area or with secure pull printing.[b][c]
- 7Recommended wayProcessPosition output devices and screens so visitors cannot see CUI: printers out of reception, privacy screens where monitors face windows or walkways, and clean-desk rules.[c]
- 8
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Physical access authorization list[a]
The detail for 6 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
7 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- Server or network equipment in an unlocked closet shared with cleaning supplies.
- Badge system still has former employees and contractors enabled.
- Controlled area defined on paper but the door is propped open all day.
- Shared-building landlord, cleaning crew or other tenants with keys to your suite that you never accounted for.
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: PE.L1-b.1.viii, PE.L2-3.10.2, PE.L2-3.10.3, PE.L2-3.10.5, MP.L2-3.8.1
Editorial implementation guidance published November 14, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.10.1SP 800-171 Rev 3
03.10.01SP 800-53 Rev 5
PE-2DSPE-4DPE-5DPE-6DHow these were reachedHide how these were reached
- PE-2 · Physical Access Authorizations
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-2 → 800-53 Rev 5 PE-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.01 → 800-53 Rev 5 PE-2
- PE-4 · Access Control for Transmission
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-4 → 800-53 Rev 5 PE-4
- PE-5 · Access Control for Output Devices
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-5 → 800-53 Rev 5 PE-5
- PE-6 · Monitoring Physical Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-6 → 800-53 Rev 5 PE-6
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (11 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- PE.L2-3.10.1 → 3.10.1“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
NIST SP 800-53 Rev 4 → Rev 5 comparison NIST
- PE-2 → PE-2“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 563
- PE-4 → PE-4“Changes title Changes parameter Changes discussion”sheet "Rev4 Rev5 Compared" row 576
- PE-5 → PE-5“Adds parameter”sheet "Rev4 Rev5 Compared" row 577
- PE-6 → PE-6“Changes discussion”sheet "Rev4 Rev5 Compared" row 581
Trace notes
Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.
About this practice
Expert CMMC note
NIST SP 800-171 Rev 2 Appendix D maps 3.10.1 and 3.10.2 jointly. PE-6 (monitoring) implements 3.10.2; PE-2, PE-4 and PE-5 implement 3.10.1.
Relies on: NIST SP 800-171 Rev 2
About SP 800-171 Rev 2 3.10.1
Expert CMMC note3.10.1 ↔ PE-6 (SP 800-53 Rev 4)
NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.10.1 and 3.10.2 jointly to PE-2, PE-4, PE-5, PE-6. PE-6 mainly supports 3.10.2, not 3.10.1 specifically.
Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10
Expert CMMC note
See also SP 800-171 Rev 3 03.10.07. Rev 3 split 3.10.1: 03.10.01 keeps the authorization list; enforcing physical access (PE-3) moved to 03.10.07 per the CUI overlay.
Relies on: NIST SP 800-171 Rev 2; NIST SP 800-171 Rev 3; NIST SP 800-171 Rev 3 CUI overlay
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Restrict physical access to systems, equipment, and operating environments to authorized individuals.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You manage a DoD project that requires special equipment used only by project team members [b,c]. You work with the facilities manager to put locks on the doors to the areas where the equipment is stored and u sed [b,c,d]. Project team members are the only individuals issued with keys to the space. This restricts access to only those employees who work on the DoD project and require access to that equipment.
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Physical and environmental protection policy; procedures addressing physical access authorizations; system security plan; authorized personnel access list; authorization credentials; physical access list reviews; physical access termination records and associated documentation; other relevant documents or records
Common mistakes
Protecting a central room while overlooking other locations containing in-scope systems.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.