PE.L2-3.10.5
Manage Physical Access [CUI Data]
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- aphysical access devices are identified;
- bphysical access devices are controlled; and
- cphysical access devices are managed.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Know every physical access device you have (keys, badges, fobs, alarm codes, door combinations), keep them under control so only authorized people hold or can issue them, and manage them over their life: issue on approval, collect and disable at departure, rekey or change codes when something is lost. A key and badge inventory reconciled against people is the core evidence.
- 1ProcessBuild an inventory of physical access devices: each key (with stamp or serial number and the doors it opens), badge or fob (with ID number and door groups), alarm user code and combination, and who holds each one. Include spares and master keys.[a]
- 2TechnicalControl the devices: keep spare keys, unassigned badges and blank cards in a locked key cabinet; use restricted keyway locks so keys cannot be copied at a hardware store; limit who can program the badge system or alarm panel to named administrators with their own logins.[b]
- 3ProcessIssue devices only with documented approval tied to the physical access authorization list; holders sign for keys and badges.[b]
- 4ProcessManage changes: disable badges and collect keys the same day someone leaves (part of the offboarding checklist), update door groups when roles change, change alarm codes and combinations after departures, and rekey locks when a key is lost or not returned.[c]
- 5
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
Physical access device inventory[a]
record · reconciled quarterly
Spreadsheet or access-control system export of keys, badges, codes, holders and doors.
Key and badge issuance records[b]
record · for every current holder
Signed key or badge receipts and approvals.
Access-control administrator list[b]
record · dated within 90 days
List of people who can program the badge system or alarm panel, with the system's admin user export.
Revocation and rekey records[c]
record · every change in the assessment period
Offboarding checklist entries, badge-system audit log of disablements, locksmith invoices for rekeying, alarm code change records.
How assessors check
- Examine
- Physical access procedures, inventory of physical access devices, issuance and revocation records, access-control system configuration and audit logs.
- Interview
- The facility manager or person who manages keys and badges; the access-control system administrator.
- Test
- Pick a key from the inventory and locate its holder; pick a departed employee and show the badge is disabled; open the key cabinet and reconcile spares; show who can program the badge system.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
Patented keyways prevent unauthorized copies; makes a key inventory meaningful.
Industry standard for tracking key checkout with audit trails in larger facilities.
An inexpensive lock box plus a dated spreadsheet is perfectly acceptable for a small office.
Instant badge revocation and an audit trail of changes.
Cloud access control with identity-provider integration and reporting; per-door licensing.
A dated inventory of every key, badge and code with its holder is perfectly acceptable for a small office when it is reconciled quarterly.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- No inventory of who has keys, and keys stamped 'Do Not Duplicate' that were copied anyway.
- Badges of departed staff still active because nobody told the office manager.
- One shared alarm code used by everyone for years.
- Badge system admin login shared or still held by the installer.
Platform notes
Microsoft 365 (GCC / GCC High)
Not applicable for the physical devices. If your badge system supports single sign-on, connect it to Entra ID so badge administration follows your identity controls.
Google Workspace
Not applicable for the physical devices; some cloud access systems can sync users from Google Workspace to speed up revocation.
On-premises or MSP-managed
Tie badge disablement into the same offboarding ticket the MSP uses to disable accounts, so physical and logical access are revoked together.
Related practices: PE.L1-b.1.ix, PE.L2-3.10.1, PE.L2-3.10.4, PS.L2-3.9.2
Editorial implementation guidance published November 2, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.10.5SP 800-171 Rev 3
03.10.0703.10.05 withdrawn; incorporated intoSP 800-53 Rev 4
PE-3SP 800-53 Rev 5
PE-3DSPE-5SHow these were reachedHide how these were reached
- PE-3 · Physical Access Control
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-3 → 800-53 Rev 5 PE-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-3NIST: 03.10.07 also: 3.10.3, 3.10.4 incorporated into
- PE-5 · Access Control for Output Devices
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-5NIST: 03.10.07 also: 3.10.3, 3.10.4 incorporated into
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (7 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- PE.L2-3.10.5 → 3.10.5“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Control and manage physical access devices.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You are a facility manager. A team member retired today and returns their company keys to you. The project on which they were working requires access to areas that contain equipment with CUI. You receive the keys, check your electronic records against the seria l numbers on the keys to ensure all have been returned, and mark each key returned [c].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Physical and environmental protection policy; procedures addressing physical access control; system security plan; physical access control logs or records; inventory records of physical access control devices; system entry and exit points; records of key and lock combination changes; storage locations for physical access control devices; physical access control devices; list of security safeguards controlling access to designated publicly accessible areas within facility; other relevant documents or records
Common mistakes
Failing to recover, revoke, inventory, or replace keys and badges as circumstances change.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/