Crosswalk
CMMC to NIST Crosswalk
Each CMMC practice with the NIST SP 800-171 Rev 2 requirement it is built on, the Rev 3 counterpart, the SP 800-53 Rev 4 and Rev 5 controls behind it and, for Level 3, the SP 800-172 requirement and its Rev 3 successor. Open any number to read it.
Filters1 on
15 practices · Level 1 · Clear
About these relationships
Mappings are the guides' key references and NIST's published relationships; a practice with no mapping yet shows a dash. Every cell comes from an official NIST or DoD table: Rev 3 entries from NIST's change analyses (a withdrawn requirement leads to the requirement NIST says replaces it), Rev 4 controls from SP 800-171 Rev 2 Appendix D, and each Rev 5 control carries the path that reached it.
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Spot an error? Email [email protected] with the practice number and the official document you are reading.
- AC.L1-b.1.iAuthorized Access Control [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 56
AC-2DSAC-2(3)SAC-2(5)SAC-2(13)SAC-3DAC-17DHow these were reachedHide how these were reached
- AC-2 · Account Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(3) · Account Management | Disable Accounts
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(3)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(5) · Account Management | Inactivity Logout
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(5)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(13) · Account Management | Disable Accounts for High-risk Individuals
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(13)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-3 · Access Enforcement
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
- AC-17 · Remote Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - AC-2 · Account Management
- AC.L1-b.1.iiTransaction & Function Control [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
AC-2DAC-3DSAC-17DHow these were reachedHide how these were reached
- AC-2 · Account Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
- AC-3 · Access Enforcement
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.02 → 800-53 Rev 5 AC-3NIST: 03.01.02 also: 3.13.3 addressed by
- AC-17 · Remote Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - AC-2 · Account Management
- AC.L1-b.1.iiiExternal Connections [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
AC-20DSAC-20(1)DSAC-20(2)SHow these were reachedHide how these were reached
- AC-20 · Use of External Systems
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 → 800-53 Rev 5 AC-20
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20NIST: 03.01.20 also: 3.1.21 incorporated into
- AC-20(1) · Use of External Systems | Limits on Authorized Use
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 (1) → 800-53 Rev 5 AC-20(1)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(1)NIST: 03.01.20 also: 3.1.21 incorporated into
- AC-20(2) · Use of External Systems | Portable Storage Devices — Restricted Use
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(2)NIST: 03.01.20 also: 3.1.21 incorporated into
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - AC-20 · Use of External Systems
- AC.L1-b.1.ivControl Public Information [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 41
NIST SP 800-53 Rev 51
AC-22DSHow these were reachedHide how these were reached
- AC-22 · Publicly Accessible Content
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-22 → 800-53 Rev 5 AC-22
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.22 → 800-53 Rev 5 AC-22
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - AC-22 · Publicly Accessible Content
- IA.L1-b.1.vIdentification [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 54
IA-2DSIA-3DIA-5DIA-11SHow these were reachedHide how these were reached
- IA-2 · Identification and Authentication (organizational Users)
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-2 → 800-53 Rev 5 IA-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.01 → 800-53 Rev 5 IA-2
- IA-3 · Device Identification and Authentication
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-3 → 800-53 Rev 5 IA-3
- IA-5 · Authenticator Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-5 → 800-53 Rev 5 IA-5
- IA-11 · Re-authentication
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.01 → 800-53 Rev 5 IA-11
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - IA-2 · Identification and Authentication (organizational Users)
- IA.L1-b.1.viAuthentication [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
IA-2DIA-3DSIA-5DHow these were reachedHide how these were reached
- IA-2 · Identification and Authentication (organizational Users)
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-2 → 800-53 Rev 5 IA-2
- IA-3 · Device Identification and Authentication
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-3 → 800-53 Rev 5 IA-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.02 → 800-53 Rev 5 IA-3
- IA-5 · Authenticator Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-5 → 800-53 Rev 5 IA-5
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - IA-2 · Identification and Authentication (organizational Users)
- MP.L1-b.1.viiMedia Disposal [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
MP-2DMP-4DMP-6DSHow these were reachedHide how these were reached
- MP-2 · Media Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-2 → 800-53 Rev 5 MP-2
- MP-4 · Media Storage
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-4 → 800-53 Rev 5 MP-4
- MP-6 · Media Sanitization
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-6 → 800-53 Rev 5 MP-6
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.08.03 → 800-53 Rev 5 MP-6NIST: 03.08.03 also: 3.7.3 incorporated into
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - MP-2 · Media Access
- PE.L1-b.1.ixManage Visitors & Physical Access [FCI Data]
NIST SP 800-171 Rev 33
NIST SP 800-53 Rev 41
NIST SP 800-53 Rev 52
PE-3DSPE-5SHow these were reachedHide how these were reached
- PE-3 · Physical Access Control
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-3 → 800-53 Rev 5 PE-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-3NIST: 03.10.07 also: 3.10.4, 3.10.5 incorporated into
- PE-5 · Access Control for Output Devices
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-5NIST: 03.10.07 also: 3.10.4, 3.10.5 incorporated into
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - PE-3 · Physical Access Control
- PE.L1-b.1.viiiLimit Physical Access [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 54
PE-2DSPE-4DPE-5DPE-6DHow these were reachedHide how these were reached
- PE-2 · Physical Access Authorizations
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-2 → 800-53 Rev 5 PE-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.01 → 800-53 Rev 5 PE-2
- PE-4 · Access Control for Transmission
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-4 → 800-53 Rev 5 PE-4
- PE-5 · Access Control for Output Devices
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-5 → 800-53 Rev 5 PE-5
- PE-6 · Monitoring Physical Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-6 → 800-53 Rev 5 PE-6
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - PE-2 · Physical Access Authorizations
- SC.L1-b.1.xBoundary Protection [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 52
SA-8DSC-7DSHow these were reachedHide how these were reached
- SA-8 · Security and Privacy Engineering Principles
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SA-8 → 800-53 Rev 5 SA-8
- SC-7 · Boundary Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: 3.13.5 incorporated into; SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SA-8 · Security and Privacy Engineering Principles
- SC.L1-b.1.xiPublic-Access System Separation [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
03.13.0103.13.05 withdrawn; incorporated intoNIST SP 800-53 Rev 41
NIST SP 800-53 Rev 51
SC-7DSHow these were reachedHide how these were reached
- SC-7 · Boundary Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SC-7 · Boundary Protection
- SI.L1-b.1.xiiFlaw Remediation [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
SI-2DSSI-3DSI-5DHow these were reachedHide how these were reached
- SI-2 · Flaw Remediation
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-2 → 800-53 Rev 5 SI-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.01 → 800-53 Rev 5 SI-2
- SI-3 · Malicious Code Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
- SI-5 · Security Alerts, Advisories, and Directives
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-5 → 800-53 Rev 5 SI-5
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SI-2 · Flaw Remediation
- SI.L1-b.1.xiiiMalicious Code Protection [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
NIST SP 800-53 Rev 53
SI-2DSI-3DSSI-5DHow these were reachedHide how these were reached
- SI-2 · Flaw Remediation
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-2 → 800-53 Rev 5 SI-2
- SI-3 · Malicious Code Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.4 incorporated into; 3.14.5 addressed by
- SI-5 · Security Alerts, Advisories, and Directives
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-5 → 800-53 Rev 5 SI-5
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SI-2 · Flaw Remediation
- SI.L1-b.1.xivUpdate Malicious Code Protection [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
03.14.0203.14.04 withdrawn; incorporated intoNIST SP 800-53 Rev 41
NIST SP 800-53 Rev 51
SI-3DSHow these were reachedHide how these were reached
- SI-3 · Malicious Code Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.5 addressed by
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SI-3 · Malicious Code Protection
- SI.L1-b.1.xvSystem & File Scanning [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-171 Rev 31
03.14.0203.14.05 withdrawn; addressed byNIST SP 800-53 Rev 41
NIST SP 800-53 Rev 51
SI-3DSHow these were reachedHide how these were reached
- SI-3 · Malicious Code Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.4 incorporated into
NIST SP 800-172 (Feb 2021)—
—NIST SP 800-172 Rev 3—
— - SI-3 · Malicious Code Protection