Skip to content

Crosswalk

CMMC to NIST Crosswalk

Each CMMC practice with the NIST SP 800-171 Rev 2 requirement it is built on, the Rev 3 counterpart, the SP 800-53 Rev 4 and Rev 5 controls behind it and, for Level 3, the SP 800-172 requirement and its Rev 3 successor. Open any number to read it.

Filters1 on

15 practices · Level 1 · Clear

About these relationships

Mappings are the guides' key references and NIST's published relationships; a practice with no mapping yet shows a dash. Every cell comes from an official NIST or DoD table: Rev 3 entries from NIST's change analyses (a withdrawn requirement leads to the requirement NIST says replaces it), Rev 4 controls from SP 800-171 Rev 2 Appendix D, and each Rev 5 control carries the path that reached it.

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Spot an error? Email [email protected] with the practice number and the official document you are reading.

  1. AC.L1-b.1.iAuthorized Access Control [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 56
    AC-2DSAC-2(3)SAC-2(5)SAC-2(13)SAC-3DAC-17D
    How these were reached
    • AC-2 · Account Management
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
    • AC-2(3) · Account Management | Disable Accounts
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(3)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
    • AC-2(5) · Account Management | Inactivity Logout
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(5)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
    • AC-2(13) · Account Management | Disable Accounts for High-risk Individuals
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(13)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
    • AC-3 · Access Enforcement
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
    • AC-17 · Remote Access
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  2. AC.L1-b.1.iiTransaction & Function Control [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 53
    AC-2DAC-3DSAC-17D
    How these were reached
    • AC-2 · Account Management
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
    • AC-3 · Access Enforcement
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.02 → 800-53 Rev 5 AC-3NIST: 03.01.02 also: 3.13.3 addressed by
    • AC-17 · Remote Access
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  3. AC.L1-b.1.iiiExternal Connections [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 42
    NIST SP 800-53 Rev 53
    AC-20DSAC-20(1)DSAC-20(2)S
    How these were reached
    • AC-20 · Use of External Systems
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 → 800-53 Rev 5 AC-20
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20NIST: 03.01.20 also: 3.1.21 incorporated into
    • AC-20(1) · Use of External Systems | Limits on Authorized Use
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 (1) → 800-53 Rev 5 AC-20(1)
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(1)NIST: 03.01.20 also: 3.1.21 incorporated into
    • AC-20(2) · Use of External Systems | Portable Storage Devices — Restricted Use
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(2)NIST: 03.01.20 also: 3.1.21 incorporated into
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  4. AC.L1-b.1.ivControl Public Information [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 41
    NIST SP 800-53 Rev 51
    AC-22DS
    How these were reached
    • AC-22 · Publicly Accessible Content
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-22 → 800-53 Rev 5 AC-22
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.22 → 800-53 Rev 5 AC-22
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  5. IA.L1-b.1.vIdentification [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 54
    IA-2DSIA-3DIA-5DIA-11S
    How these were reached
    • IA-2 · Identification and Authentication (organizational Users)
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-2 → 800-53 Rev 5 IA-2
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.01 → 800-53 Rev 5 IA-2
    • IA-3 · Device Identification and Authentication
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-3 → 800-53 Rev 5 IA-3
    • IA-5 · Authenticator Management
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-5 → 800-53 Rev 5 IA-5
    • IA-11 · Re-authentication
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.01 → 800-53 Rev 5 IA-11
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  6. IA.L1-b.1.viAuthentication [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 53
    IA-2DIA-3DSIA-5D
    How these were reached
    • IA-2 · Identification and Authentication (organizational Users)
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-2 → 800-53 Rev 5 IA-2
    • IA-3 · Device Identification and Authentication
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-3 → 800-53 Rev 5 IA-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.05.02 → 800-53 Rev 5 IA-3
    • IA-5 · Authenticator Management
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 IA-5 → 800-53 Rev 5 IA-5
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  7. MP.L1-b.1.viiMedia Disposal [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 53
    MP-2DMP-4DMP-6DS
    How these were reached
    • MP-2 · Media Access
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-2 → 800-53 Rev 5 MP-2
    • MP-4 · Media Storage
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-4 → 800-53 Rev 5 MP-4
    • MP-6 · Media Sanitization
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MP-6 → 800-53 Rev 5 MP-6
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.08.03 → 800-53 Rev 5 MP-6NIST: 03.08.03 also: 3.7.3 incorporated into
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  8. PE.L1-b.1.ixManage Visitors & Physical Access [FCI Data]
    NIST SP 800-171 Rev 23
    NIST SP 800-171 Rev 33
    03.10.0703.10.03 withdrawn; incorporated into03.10.0703.10.04 withdrawn; incorporated into03.10.0703.10.05 withdrawn; incorporated into
    NIST SP 800-53 Rev 41
    NIST SP 800-53 Rev 52
    PE-3DSPE-5S
    How these were reached
    • PE-3 · Physical Access Control
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-3 → 800-53 Rev 5 PE-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-3NIST: 03.10.07 also: 3.10.4, 3.10.5 incorporated into
    • PE-5 · Access Control for Output Devices
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.07 → 800-53 Rev 5 PE-5NIST: 03.10.07 also: 3.10.4, 3.10.5 incorporated into
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  9. PE.L1-b.1.viiiLimit Physical Access [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 44
    NIST SP 800-53 Rev 54
    PE-2DSPE-4DPE-5DPE-6D
    How these were reached
    • PE-2 · Physical Access Authorizations
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-2 → 800-53 Rev 5 PE-2
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.01 → 800-53 Rev 5 PE-2
    • PE-4 · Access Control for Transmission
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-4 → 800-53 Rev 5 PE-4
    • PE-5 · Access Control for Output Devices
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-5 → 800-53 Rev 5 PE-5
    • PE-6 · Monitoring Physical Access
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-6 → 800-53 Rev 5 PE-6
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  10. SC.L1-b.1.xBoundary Protection [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 42
    NIST SP 800-53 Rev 52
    SA-8DSC-7DS
    How these were reached
    • SA-8 · Security and Privacy Engineering Principles
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SA-8 → 800-53 Rev 5 SA-8
    • SC-7 · Boundary Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: 3.13.5 incorporated into; SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  11. SC.L1-b.1.xiPublic-Access System Separation [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    03.13.0103.13.05 withdrawn; incorporated into
    NIST SP 800-53 Rev 41
    NIST SP 800-53 Rev 51
    SC-7DS
    How these were reached
    • SC-7 · Boundary Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  12. SI.L1-b.1.xiiFlaw Remediation [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 53
    SI-2DSSI-3DSI-5D
    How these were reached
    • SI-2 · Flaw Remediation
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-2 → 800-53 Rev 5 SI-2
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.01 → 800-53 Rev 5 SI-2
    • SI-3 · Malicious Code Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
    • SI-5 · Security Alerts, Advisories, and Directives
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-5 → 800-53 Rev 5 SI-5
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  13. SI.L1-b.1.xiiiMalicious Code Protection [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    NIST SP 800-53 Rev 43
    NIST SP 800-53 Rev 53
    SI-2DSI-3DSSI-5D
    How these were reached
    • SI-2 · Flaw Remediation
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-2 → 800-53 Rev 5 SI-2
    • SI-3 · Malicious Code Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.4 incorporated into; 3.14.5 addressed by
    • SI-5 · Security Alerts, Advisories, and Directives
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-5 → 800-53 Rev 5 SI-5
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  14. SI.L1-b.1.xivUpdate Malicious Code Protection [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    03.14.0203.14.04 withdrawn; incorporated into
    NIST SP 800-53 Rev 41
    NIST SP 800-53 Rev 51
    SI-3DS
    How these were reached
    • SI-3 · Malicious Code Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.5 addressed by
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —
  15. SI.L1-b.1.xvSystem & File Scanning [FCI Data]
    NIST SP 800-171 Rev 21
    NIST SP 800-171 Rev 31
    03.14.0203.14.05 withdrawn; addressed by
    NIST SP 800-53 Rev 41
    NIST SP 800-53 Rev 51
    SI-3DS
    How these were reached
    • SI-3 · Malicious Code Protection
      • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
      • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.4 incorporated into
    NIST SP 800-172 (Feb 2021)—
    —
    NIST SP 800-172 Rev 3—
    —