Skip to content
All CMMC practices
CMMC · Rev 2.13L1SC · System & Communications Protection

SC.L1-b.1.x

Boundary Protection [FCI Data]

Requirement

Monitor, control, and protect organizational communications (i.e., information transmitted or received by organizational information systems) at the external boundaries and key internal boundaries of the information systems.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. athe external system boundary is defined;
  2. bkey internal system boundaries are defined;
  3. ccommunications are monitored at the external system boundary;
  4. dcommunications are monitored at key internal boundaries;
  5. ecommunications are controlled at the external system boundary;
  6. fcommunications are controlled at key internal boundaries;
  7. gcommunications are protected at the external system boundary; and
  8. hcommunications are protected at key internal boundaries.

From the CMMC Level 1 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Know where your network ends and the internet begins, put a firewall at that edge that blocks unwanted traffic, and keep an eye on what crosses it. Inside, separate the parts that matter (the systems holding Federal Contract Information) from guest Wi-Fi, printers, cameras and other devices. For a small shop this is usually one business firewall with web filtering and a separate guest network, plus the security settings of your cloud services, which are part of the boundary too. The same requirement appears at Level 2 as SC.L2-3.13.1 for CUI.

The minimum for a small organization · Expert CMMC's reading, not official text

Know where your network meets the internet and where the parts that matter sit inside it [a] [b], and at those edges watch [c] [d], control [e] [f] and protect [g] [h] what crosses. For a small shop this is usually one business firewall that denies connections by default, allows only the ones you authorize and keeps a log, a separate guest network, and the security settings of your cloud services, which are part of the boundary too.

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeProcessDefine the external boundary (where your systems meet the internet, including your cloud services' sign-in) and the key internal boundaries (for example between guest Wi-Fi, printers and cameras, and the systems that hold FCI).[a][b]
  2. 2
    Required outcomeTechnicalControl communications at those boundaries: connections are denied by default and only authorized ones are allowed at the edge, and guest and device networks cannot reach the systems that hold FCI.[e][f]

    You can tell it worked when a connection from the guest network to an internal FCI system is refused, and an external scan finds no service you did not intend to expose.

  3. 3
    Required outcomeTechnicalMonitor communications at those boundaries: the edge and internal-segment controls record what they block or allow, and someone looks at it.[c][d]
  4. 4
    Required outcomeTechnicalProtect communications crossing those boundaries: remote access and administration only over encrypted connections, and the internal wireless network protected by encryption.[g][h]
  5. 5
    Recommended wayProcessDraw a simple network diagram: internet connections, firewall, Wi-Fi, switches, servers, your cloud services and where FCI lives, with the boundaries marked.[a][b]
  6. 6
    Recommended wayTechnicalUse a business-grade firewall rather than the ISP's router: deny by default and allow only documented, approved connections, no port forwards unless documented and approved (never remote desktop), UPnP off, the admin page not reachable from the internet, and separate VLANs and SSIDs for guests and IoT devices.[e][f]
  7. 7
    Recommended wayTechnicalTurn on web or DNS filtering that blocks known malicious and newly registered domains, as the firewall's subscription or a DNS filtering service, and an endpoint agent or the device's built-in network protection for laptops away from the office.[c][e][g]
  8. 8
    Recommended wayTechnicalLog denied traffic at the edge and between internal segments, keep the logs for a period you set (90 days is common), and have the firewall send a digest of blocked activity.[c][d]
  9. 9
    Recommended wayTechnicalUse a VPN for remote access to office systems, HTTPS for cloud services, WPA3 or WPA2-Enterprise (or at minimum WPA2 with a long passphrase) on internal Wi-Fi, and HTTPS or SSH for firewall and switch management from the inside only.[g][h]
  10. 10
    Recommended wayProcessRead the blocked-traffic digest and review the firewall rules on a schedule you set (monthly and quarterly are common); remove rules nobody can explain and record the date, reviewer and changes.[c][d][e][f]

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

The detail for 6 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Fortinet FortiGateBusiness firewall with web filteringPaid
Cisco Meraki MXCloud-managed firewallPaid
Ubiquiti UniFi gatewaysFirewall and Wi-Fi for small officesPaid
pfSense CE or OPNsenseOpen-source firewallFree
Cloudflare Zero Trust (Gateway)DNS and web filteringFree tier
Quad9DNS filteringFree

23 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

  • Using the ISP-supplied router as the only firewall, with UPnP on and default admin credentials.
  • One flat network where guest Wi-Fi, security cameras, the shop-floor PC and the FCI file server all see each other.
  • Forgetting the cloud: if FCI lives in Microsoft 365 or Google Workspace, the tenant's sign-in and sharing settings are part of the external boundary.
  • A port forward for remote desktop or a NAS added years ago and never removed.
  • Logging turned on but kept only on the device, overwritten after a few days, and never looked at.

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: SC.L1-b.1.xi, AC.L1-b.1.iii, AC.L1-b.1.i, SC.L2-3.13.1

Editorial implementation guidance published November 14, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.13.1

SP 800-171 Rev 3

03.13.01

SP 800-53 Rev 4

SA-8SC-7

SP 800-53 Rev 5

SA-8DSC-7DS
How these were reached
  • SA-8 · Security and Privacy Engineering Principles
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SA-8 → 800-53 Rev 5 SA-8
  • SC-7 · Boundary Protection
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: 3.13.5 incorporated into; SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (7 links from 5 official documents)

CMMC Assessment Guide Level 1 v2.13 DoD CIO

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.13.1 → 03.13.01“Significant Change”sheet "Change Analysis 800-171 R2-R3" row 99

NIST SP 800-171 Rev 2 NIST

  • 3.13.1 → SA-8“Appendix D mapping”p.93 Table D-13
  • 3.13.1 → SC-7“Appendix D mapping”p.93 Table D-13

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • SA-8 → SA-8“Changes title Changes control text Adds parameter Changes discussion Adds to L Security Control Baseline (SP 800-53B)”sheet "Rev4 Rev5 Compared" row 767
  • SC-7 → SC-7“Changes control text”sheet "Rev4 Rev5 Compared" row 903

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.13.01 → SC-7“Source control”control 03.13.01 link rel=reference (SC-07)

Trace notes

Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.

About this practice

  • Expert CMMC note

    Listed because SP 800-171 Rev 2 App. D maps basic requirements 3.13.1 and 3.13.2 jointly to one cell. SA-8 (security engineering principles) is the source for 3.13.2; it does not address boundary monitoring/control.

    Relies on: NIST SP 800-171 Rev 2, Appendix D, Table D-13

About SP 800-171 Rev 2 3.13.1

  • Expert CMMC note3.13.1 ↔ SA-8 (SP 800-53 Rev 4)

    NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.13.1 and 3.13.2 jointly to SC-7, SA-8. SA-8 mainly supports 3.13.2, not 3.13.1 specifically.

    Relies on: NIST SP 800-171 Rev 2, p.93, Appendix D, Table D-13

Further discussion

Fences, locks, badges, and key cards help keep non-employees out of your physical facilities. Similarly, your company’s IT network or system has boundaries that must be protected. Many companies use a web proxy and a firewall. When an employee uses a company computer to go to a website, a web proxy makes the request on the user’s behalf, looks at the web request, and decides if it should let the employee go to the website. A firewall controls access from the inside and outside, protecting valuable information and resources stored on the company’s network. A firewall stops unwanted traffic on the internet from passing through an outside “fence” to the company’s networks and information systems. Internal boundaries determine where data can flow, for instance a software development environment may have its own boundary controlling, monitoring, and protecting the data that can leave that boundary. It may be wise to monitor, control, or protect one part of the company network from another. This can also be accomplished with a firewall and limits the ability of attackers and disgruntled employees from entering sensitive parts of your internal network and causing damage. Example You are setting up the new network with an FCI enclave. You start by sketching out a simple diagram that identifies the external boundary of your network and any internal boundaries that are needed [a,b]. The first piece of equipment you install is the firewall, a device to separate your internal network from the internet. The firewall also has a feature that allows you to block access to potentially malicious websites, and you configure that service as well [a,c,e,g]. Some of your coworkers complain that they cannot get to certain websites [c,e,g]. You explain that the new network blocks websites that are known for spreading malware. The firewall sends you a daily digest of blocked activity so that you can monitor the system for attack trends [c,d]. Potential Assessment Considerations • What are the external system boundary components that make up the entry and exit points for data flow (e.g., firewalls, gateways, cloud service boundaries), behind which all system components that handle regulated data are contained? What are the supporting system components necessary for the protection of regulated data [a]? • What are the internal system boundary components that make up the entry and exit points for key internal data flow (e.g., internal firewalls, routers, any devices that can bridge the connection between one segment of the system and another) that separate segments of the internal network – including devices that separate internal network segments such as development and production networks as well as a traditional DMZ at the edge of the network [b]? • Is data flowing in and out of the external and key internal system boundaries monitored (e.g., connections are logged and able to be reviewed, suspicious traffic generates alerts) [c,d]? • Is data traversing the external and internal system boundaries controlled such that connections are denied by default and only authorized connections are allowed [e,f]? • Is data flowing in and out of the external and key internal system boundaries protected (e.g., applying encryption when required or prudent, tunneling traffic as needed) [g,h]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Control and protect communications crossing external and important internal system boundaries.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You are setting up the new network with an FCI enclave. You start by sketching out a simple diagram that identifies the external boundary of your network and any internal boundaries that are needed [a,b]. The first piece of equipment you install is the firewall, a device to 26 NIST SP 800-171 Rev. 2, p. 36 separate your internal network from the internet. The firewall also has a feature that allows you to block access to potentially malicious websites, and you configure that service as well [a,c,e,g]. Some of your coworkers complain that they cannot get to certain websites [c,e,g]. You explain that the new network blocks websites that are known for spreading malware. The firewall sends you a daily digest of blocked activity so that you can monitor the system for attack trends [c,d].

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): System and communications protection policy; procedures addressing boundary protection; system security plan; list of key internal boundaries of the system; system design documentation; boundary protection hardware and software; enterprise security architecture documentation; system audit logs and records; system configuration settings and associated documentation; other relevant documents or records

Common mistakes

Assuming an installed firewall proves every required boundary is identified and protected.

Track this in a workspace

The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Source: DoD CIO · https://dodcio.defense.gov/CMMC/