CMMC · Rev 2.13L2PE · Physical Protection

PE.L2-3.10.2

Monitor Facility

Requirement

Protect and monitor the physical facility and support infrastructure for organizational systems.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. athe physical facility where organizational systems reside is protected;
  2. bthe support infrastructure for organizational systems is protected;
  3. cthe physical facility where organizational systems reside is monitored; and
  4. dthe support infrastructure for organizational systems is monitored.

From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Protect the building where your CUI systems live and the infrastructure that supports them (power, network cabling, wiring closets, HVAC for the server room), and monitor both so you notice and respond to break-ins, tampering and environmental problems. For a small contractor: solid locks on doors and windows, a monitored alarm, cameras at entrances, locked wiring closets and cable runs, and someone who actually reviews alerts.

The minimum for a small organization · Expert CMMC's reading, not official text

Protect the building where your systems are, and the power, cabling and cooling they depend on [a] [b], and monitor both so a physical security incident is noticed and acted on [c] [d]. Locked entrances, an intrusion alarm or cameras on entrances and the server room, locked wiring closets, with alarm or camera alerts going to a named person who responds, are the usual way for a small shop.

Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeTechnicalProtect the facility where CUI systems are and the infrastructure they depend on.[a][b]
    SourceCMMC Assessment Guide Level 2 v2.13objectives [a] and [b], p.190
    Quoted words
    • “the physical facility where organizational systems reside is protected”
    • “the support infrastructure for organizational systems is protected”
  2. 2
    Recommended wayTechnicalFor objectives [a] and [b], put secure locks on entrances, exits and accessible windows, and keep power and network cabling, wiring closets and electrical panels out of reach of visitors and unauthorized staff. The guide's discussion names locked wiring closets, disconnected or locked spare jacks and cabling protected by conduit or cable trays (L2 guide p.190), and its further discussion says infrastructure such as power and network cables is protected so that visitors and unauthorized employees cannot access it (L2 guide p.191).[a][b]

    You can tell it worked when a walk-through finds entrances, exits and windows secured, and wiring closets, panels and cable runs locked or out of reach of visitors.

    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2andCMMC Assessment Guide Level 2 v2.13p.191 PE.L2-3.10.2
  3. 3
    Required outcomeTechnicalMonitor the facility and that infrastructure.[c][d]
    SourceCMMC Assessment Guide Level 2 v2.13objectives [c] and [d], p.190
    Quoted words
    • “the physical facility where organizational systems reside is monitored”
    • “the support infrastructure for organizational systems is monitored”
  4. 4
    Recommended wayTechnicalFor objectives [c] and [d], cover entrances, exits, the server room and wiring closets with cameras, guards, sensors or alarms that report to a named person who responds. The guide's discussion gives guards, sensor devices and video cameras as examples (L2 guide p.190), and its assessment consideration asks whether physical access is monitored to detect and respond to physical security incidents (L2 guide p.191).[c][d]

    You can tell it worked when entrances, exits, the server room and wiring closets are watched by cameras, guards, sensors or an alarm, and a named person receives and acts on what they report.

    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2andCMMC Assessment Guide Level 2 v2.13p.191 PE.L2-3.10.2
  5. 5
    Recommended wayPolicyDocument in the physical security policy what is protected (facility perimeter, CUI areas, server and network rooms, power panels, cabling, UPS and HVAC that support IT), how it is monitored, who receives alerts and who responds to physical security incidents.[a][b][c][d]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2
  6. 6
    Recommended wayTechnicalProtect the facility: secure locks on all entrances, exits and accessible windows, intrusion alarm on perimeter doors, and controlled entry to CUI areas.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2
  7. 7
    Recommended wayTechnicalProtect support infrastructure: lock wiring closets and electrical panels serving IT, run network cabling through walls, ceilings or conduit rather than exposed in public areas, disable or lock unused network jacks in public spaces, and put servers and network gear on a UPS.[b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2
  8. 8
    Recommended wayTechnicalMonitor the facility: cameras covering entrances, exits and the server room, recorded to an NVR or cloud service with a defined retention period; intrusion alarm monitored by a central station or sending alerts to named people.[c]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2
  9. 9
    Recommended wayTechnicalMonitor support infrastructure: UPS alerts (power loss, battery), temperature and water-leak sensors in the server room, door-open alerts on wiring closets, and network alerts when a switch port in a public area goes live.[d]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2
  10. 10
    Recommended wayProcessRespond and review: define who acts on alarms and alerts, review camera footage after incidents and spot-check monthly, test the alarm and sensors at least annually, and log incidents and tests.[c][d]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.190 PE.L2-3.10.2

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

Facility diagram with protections and monitoring[a][b][c][d]

Also supports 2 other practices: keep it once

Camera and alarm system configuration[c]

Also supports 1 other practice: keep it once

Infrastructure monitoring alerts[d]

Monitoring review and test log[c][d]

Photos of protected infrastructure[a][b]

Also supports 2 other practices: keep it once

The detail for 6 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Verkada cameras and environmental sensorsEnterprise video and sensor monitoringEnterprise pricing
UniFi ProtectVideo surveillancePaid
Monitored intrusion alarm (ADT or a local alarm company; SimpliSafe for very small offices)Intrusion detectionPaid
APC NetBotz or UPS network management cardInfrastructure monitoringPaid
Locking wall-mount rack and conduit for cable runsInfrastructure protectionPaid
Monitoring review and test log (spreadsheet or ticket)RecordsFree

Notes on 6 products for this practice: why each matters here, what it assumes and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: PE.L2-3.10.1, PE.L2-3.10.4, PE.L2-3.10.3, IR.L2-3.6.1

Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.10.2

SP 800-171 Rev 3

03.10.02

SP 800-53 Rev 4

PE-2PE-4PE-5PE-6

SP 800-53 Rev 5

PE-2DPE-4DPE-5DPE-6DS
How these were reached
  • PE-2 · Physical Access Authorizations
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-2 → 800-53 Rev 5 PE-2
  • PE-4 · Access Control for Transmission
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-4 → 800-53 Rev 5 PE-4
  • PE-5 · Access Control for Output Devices
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-5 → 800-53 Rev 5 PE-5
  • PE-6 · Monitoring Physical Access
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-6 → 800-53 Rev 5 PE-6
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.02 → 800-53 Rev 5 PE-6

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (11 links from 5 official documents)

32 CFR Part 170 Office of the Federal Register / GPO

  • PE.L2-3.10.2 → 3.10.2“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.10.2 → 03.10.02“Significant Change”sheet "Change Analysis 800-171 R2-R3" row 83

NIST SP 800-171 Rev 2 NIST

  • 3.10.2 → PE-2“Appendix D mapping”p.90 Table D-10
  • 3.10.2 → PE-4“Appendix D mapping”p.90 Table D-10
  • 3.10.2 → PE-5“Appendix D mapping”p.90 Table D-10
  • 3.10.2 → PE-6“Appendix D mapping”p.90 Table D-10

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • PE-2 → PE-2“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 563
  • PE-4 → PE-4“Changes title Changes parameter Changes discussion”sheet "Rev4 Rev5 Compared" row 576
  • PE-5 → PE-5“Adds parameter”sheet "Rev4 Rev5 Compared" row 577
  • PE-6 → PE-6“Changes discussion”sheet "Rev4 Rev5 Compared" row 581

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.10.02 → PE-6“Source control”control 03.10.02 link rel=reference (PE-06)

Trace notes

Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.

About this practice

  • Expert CMMC note

    NIST SP 800-171 Rev 2 Appendix D maps 3.10.1 and 3.10.2 jointly. PE-2 and PE-5 implement 3.10.1; PE-6 (monitoring) implements 3.10.2; PE-4 (access to transmission lines) serves both: it limits physical access (3.10.1) and protects support infrastructure (3.10.2).

    Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10

  • Expert CMMC note

    SP 800-171 Rev 3 03.10.02 covers monitoring only. Of the 'protect' half of 3.10.2, Rev 3 keeps physical access to distribution and transmission lines, as a requirement of its own, 03.10.08 (from PE-4; NIST's change analysis lists it as new, not as a successor of 3.10.2). NIST tailored out the other controls that protect support infrastructure (PE-9 to PE-15) as not directly related to protecting the confidentiality of CUI (NCO).

    Relies on: NIST SP 800-171 Rev 2, p.45 3.10.2; NIST SP 800-171 Rev 3, pp.60-61 03.10.02; NIST SP 800-171 Rev 3, p.103 Appendix C, Table 2; NIST SP 800-171 Rev 3, p.109 Appendix C, Table 13, PE-09; NIST SP 800-171 Rev 3, p.110 Appendix C, Table 13, PE-15; NIST SP 800-171 Rev 3, p.63 03.10.08; NIST SP 800-171 Rev 3, p.109 Appendix C, Table 13, PE-04; NIST SP 800-171 Rev 2 → Rev 3 change analysis, sheet "Change Analysis 800-171 R2-R3" row 89

About SP 800-171 Rev 2 3.10.2

  • Expert CMMC note3.10.2 ↔ PE-2 (SP 800-53 Rev 4)

    NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.10.1 and 3.10.2 jointly to PE-2, PE-4, PE-5, PE-6. PE-2 mainly supports 3.10.1, not 3.10.2 specifically.

    Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10

  • Expert CMMC note3.10.2 ↔ PE-5 (SP 800-53 Rev 4)

    NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.10.1 and 3.10.2 jointly to PE-2, PE-4, PE-5, PE-6. PE-5 mainly supports 3.10.1, not 3.10.2 specifically.

    Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10

Further discussion

The infrastructure inside of a facility, such as power and network cables, is protected so that visitors and unauthorized employees cannot access it. The protection is also monitored by security guards, video cameras, sensors, or alarms. Example You are responsible for protecting your IT facilities. You install video cameras at each entrance and exit, connect them to a video recorder, and show the camera feeds on a display at the reception desk [c,d]. You also make sure there are secure locks on all entrances, exits, and windows to the facilities [a,b]. Potential Assessment Considerations • Is physical access monitored to detect and respond to physical security incidents [c,d]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Protect and monitor the physical facility and supporting infrastructure.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You are responsible for protecting your IT facilities. You install video cameras at each entrance and exit, connect them to a video recorder, and show the camera feeds on a display at the reception desk [c,d]. You also make sure there are secure locks on all entrances, exits, and windows to the facilities [a,b].

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): Physical and environmental protection policy; procedures addressing physical access monitoring; system security plan; physical access logs or records; physical access monitoring records; physical access log reviews; other relevant documents or records

Common mistakes

Relying on a locked entrance without appropriate monitoring and supporting protections.