PE.L1-b.1.viii
Limit Physical Access [FCI Data]
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- aauthorized individuals allowed physical access are identified;
- bphysical access to organizational systems is limited to authorized individuals;
- cphysical access to equipment is limited to authorized individuals; and
- dphysical access to operating environments is limited to authorized individuals.
From the CMMC Level 1 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Keep people who are not authorized away from the computers, equipment and rooms where Federal Contract Information (FCI) is handled. Write down who is allowed in, give only them keys, badges or codes, lock the office and any server or network closet, and place printers where output is not exposed to visitors. For many small shops, good locks and a current key list are the core of it.
The minimum for a small organization · Expert CMMC's reading, not official text
Keep people who are not authorized away from the computers, equipment and rooms where FCI is handled. Know who is allowed in [a], and limit physical access to systems, equipment and work areas to them [b] [c] [d]. For many small shops, locked doors, a locked network closet, a current key list and printers placed away from visitors are the usual way.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessIdentify the individuals allowed physical access to each area where FCI systems are used (office, server or network closet, work areas).[a]SourceCMMC Assessment Guide Level 1 v2.13objective [a], p.33
Quoted words
- “authorized individuals allowed physical access are identified”
- 2Recommended wayProcessFor objective [a], record the credential each person holds (key, badge, alarm code). The guide's assessment consideration asks whether lists of personnel with authorized access are developed and maintained and appropriate authorization credentials issued (L1 guide p.34).[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- 3Required outcomeTechnicalLimit physical access to the systems and the rooms they are in to those individuals.[b][d]
You can tell it worked when a walk-through finds every door to FCI areas locked or staffed, and every key or badge holder on the list.
SourceCMMC Assessment Guide Level 1 v2.13objectives [b] and [d], p.33Quoted words
- “physical access to organizational systems is limited to authorized individuals”
- “physical access to operating environments is limited to authorized individuals”
- 4Recommended wayTechnicalFor objectives [b] and [d], lock the exterior doors and the office suite, keep work areas closed to the public, and in a shared building leave no route in through common areas. The guide's further discussion says specific environments are limited to authorized employees, with access controlled by badges, electronic locks or physical key locks (L1 guide p.34).[b][d]Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- 5Required outcomeTechnicalLimit physical access to equipment to authorized individuals.[c]SourceCMMC Assessment Guide Level 1 v2.13objective [c], p.33
Quoted words
- “physical access to equipment is limited to authorized individuals”
- 6Recommended wayTechnicalFor objective [c], keep servers, firewalls, switches and NAS units in a locked closet or rack, lock away or cable laptops left unattended in shared areas, and place printers where their output is not exposed to people who are not authorized. The guide's discussion names placing equipment in locked rooms or other secured areas, and its assessment consideration asks whether printers are placed where their use does not expose data to unauthorized individuals (L1 guide p.34).[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- 7Recommended wayProcessPlace printers, copiers and screens that show FCI where visitors cannot see or pick up output, or use secure print release.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.33 PE.L1-b.1.viii
- 8Recommended wayProcessReview the list against actual key and badge holders on a schedule you set (yearly at least is common) and after anyone leaves, and record the review.[a][b][c][d]Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.33 PE.L1-b.1.viii
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Physical access authorization list[a]
Physical security procedure[a][b][c][d]
The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
7 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- Network closet doubles as a storage closet everyone uses, with the door propped open.Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- No list of who holds keys, or keys that were never collected from former staff.Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- Printer next to the reception area where visitors can pick up output.Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
- Assuming the building's front desk covers your office when your suite door is unlocked all day.Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.34 PE.L1-b.1.viii
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: PE.L1-b.1.ix, PE.L2-3.10.1, MP.L1-b.1.vii, AC.L1-b.1.i
Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.10.1SP 800-171 Rev 3
03.10.01SP 800-53 Rev 5
PE-2DSPE-4DPE-5DPE-6DHow these were reachedHide how these were reached
- PE-2 · Physical Access Authorizations
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-2 → 800-53 Rev 5 PE-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.10.01 → 800-53 Rev 5 PE-2
- PE-4 · Access Control for Transmission
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-4 → 800-53 Rev 5 PE-4
- PE-5 · Access Control for Output Devices
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-5 → 800-53 Rev 5 PE-5
- PE-6 · Monitoring Physical Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PE-6 → 800-53 Rev 5 PE-6
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (11 links from 5 official documents)
CMMC Assessment Guide Level 1 v2.13 DoD CIO
- PE.L1-b.1.viii → 3.10.1“Key reference”p.34 PE.L1-b.1.viii KEY REFERENCES
NIST SP 800-53 Rev 4 → Rev 5 comparison NIST
- PE-2 → PE-2“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 563
- PE-4 → PE-4“Changes title Changes parameter Changes discussion”sheet "Rev4 Rev5 Compared" row 576
- PE-5 → PE-5“Adds parameter”sheet "Rev4 Rev5 Compared" row 577
- PE-6 → PE-6“Changes discussion”sheet "Rev4 Rev5 Compared" row 581
Trace notes
Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.
About this practice
Expert CMMC note
NIST SP 800-171 Rev 2 Appendix D maps 3.10.1 and 3.10.2 jointly. PE-2 and PE-5 implement 3.10.1; PE-6 (monitoring) implements 3.10.2; PE-4 (access to transmission lines) serves both: it limits physical access (3.10.1) and protects support infrastructure (3.10.2).
Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10
About SP 800-171 Rev 2 3.10.1
Expert CMMC note3.10.1 ↔ PE-6 (SP 800-53 Rev 4)
NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.10.1 and 3.10.2 jointly to PE-2, PE-4, PE-5, PE-6. PE-6 mainly supports 3.10.2, not 3.10.1 specifically.
Relies on: NIST SP 800-171 Rev 2, p.90, Appendix D, Table D-10
Expert CMMC note
See also SP 800-171 Rev 3 03.10.07. Rev 3 split 3.10.1: 03.10.01 keeps the authorization list; enforcing physical access (PE-3) moved to 03.10.07 per the CUI overlay.
Relies on: NIST SP 800-171 Rev 2, p.45 3.10.1; NIST SP 800-171 Rev 3, pp.62-63 03.10.07; NIST SP 800-171 Rev 3, p.60 03.10.01; NIST SP 800-171 Rev 3 CUI overlay, sheet "CUI Overlay" row 688
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Restrict physical access to systems, equipment, and their operating environments to authorized people.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You manage a DoD project that stores FCI on computers used only by project team members [b,c]. You work with the facilities manager to put locks on the doors to the areas where the computers are stored and used [b,c,d]. Project team members are the only individuals issued with keys to the space. This restricts access to only those employees who work on the DoD project and require access.
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Physical and environmental protection policy; procedures addressing physical access authorizations; system security plan; authorized personnel access list; authorization credentials; physical access list reviews; physical access termination records and associated documentation; other relevant documents or records
Common mistakes
Protecting the server room while leaving workstations or other in-scope equipment accessible.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.