MA.L2-3.7.2
System Maintenance Control
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- atools used to conduct system maintenance are controlled;
- btechniques used to conduct system maintenance are controlled;
- cmechanisms used to conduct system maintenance are controlled; and
- dpersonnel used to conduct system maintenance are controlled.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Control the tools, techniques, mechanisms and people used for maintenance, because maintenance runs with elevated privileges. In practice: an approved list of maintenance tools kept up to date, documented maintenance procedures with restricted access, automated scripts and scheduled jobs that only authorized admins can change, and a named list of people (staff and MSP technicians) allowed to perform maintenance through controlled entry points.
The minimum for a small organization · Expert CMMC's reading, not official text
Control what is used to maintain your systems and who does it: the tools [a], the techniques [b], the automated mechanisms such as scripts [c], and the people [d]. Keeping an approved tool list and a list of who may do maintenance, each with a named account, and limiting the tools, the maintenance documentation, the scripts and the admin entry points to those people, is the usual way.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessControl the maintenance tools and the maintenance personnel.[a][d]SourceCMMC Assessment Guide Level 2 v2.13objectives [a] and [d], p.154
Quoted words
- “tools used to conduct system maintenance are controlled”
- “personnel used to conduct system maintenance are controlled”
- 2Recommended wayProcessFor objectives [a] and [d], keep a current list of the approved maintenance tools, and a list of the people authorized to perform maintenance (staff and service-provider technicians), each with a named account. The guide's example approves all maintenance tools and names the only people authorized to use them (L2 guide p.155).[a][d]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.155 MA.L2-3.7.2
- 3Required outcomeTechnicalControl the tools, techniques, mechanisms and personnel used for system maintenance.[a][b][c][d]SourceCMMC Assessment Guide Level 2 v2.13objectives [a], [b], [c] and [d], p.154
Quoted words
- “tools used to conduct system maintenance are controlled”
- “techniques used to conduct system maintenance are controlled”
- “mechanisms used to conduct system maintenance are controlled”
- “personnel used to conduct system maintenance are controlled”
- 4Recommended wayTechnicalFor objectives [a] to [d], use physical or logical access controls to limit to authorized people the maintenance tools, the system documentation and maintenance procedures, the automated maintenance mechanisms such as scripts and scheduled jobs, and the entry points maintenance uses, such as admin portals, local and remote consoles and equipment panels. These are the guide's four assessment considerations for this practice (L2 guide p.155).[a][b][c][d]
You can tell it worked when only people on the authorized maintenance list can reach the maintenance tools, the maintenance documentation, the scripts and scheduled jobs, and the admin portals and consoles.
Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.155 MA.L2-3.7.2 - 5Recommended wayPolicyIn the maintenance policy, define what counts as a maintenance tool (RMM agents, remote-support tools, diagnostic utilities, admin consoles, scripts, hardware tools such as USB console cables), who may approve new tools, who may perform maintenance, and the entry points maintenance may use (admin portals, console access, out-of-band management).[a][b][c][d]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- 6Recommended wayProcessKeep an approved maintenance tool list with version, owner and source. Install tools only from the vendor, keep them updated, and block or remove unapproved remote-support tools (for example personal TeamViewer or AnyDesk installs) with application control or the EDR's blocklist.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- 7Recommended wayTechnicalStore maintenance procedures, runbooks and system documentation (network diagrams, admin passwords, configuration backups) in a location limited to the IT group or MSP, and keep credentials in a password vault rather than in the documents.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- 8Recommended wayTechnicalRestrict automated maintenance mechanisms: RMM scripts, scheduled tasks, Intune remediation scripts, cron jobs and configuration-management code may be created or changed only by named administrators, and changes are logged.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- 9Recommended wayTechnicalLimit maintenance entry points to authorized personnel: named admin accounts for each staff member and MSP technician, MFA on RMM and admin portals, management interfaces on a separate VLAN or allowed only from admin workstations, and physical equipment panels or server closets locked.[d]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- 10Recommended wayProcessReview quarterly: the approved tool list against what is actually installed, RMM and admin-portal user lists, and recent script changes. Remove departed technicians promptly and record the review.[a][c][d]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Approved maintenance tool list[a]
Access permissions on maintenance documentation[b]
RMM and script permission settings[c]
Authorized maintenance personnel list[d]
Quarterly maintenance access review[a][c][d]
The detail for 6 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
10 dated vendor facts and notes on 5 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- MSP technicians sharing one RMM login, so you cannot say who performed maintenance.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2
- Multiple remote-support tools installed over the years by different vendors, some still running and unmonitored.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.154 MA.L2-3.7.2andCMMC Assessment Guide Level 2 v2.13p.155 MA.L2-3.7.2
- Admin passwords stored in the network documentation spreadsheet that the whole office can read.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.155 MA.L2-3.7.2
- Firewall and switch management interfaces reachable from the general office network or the internet.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.155 MA.L2-3.7.2
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: MA.L2-3.7.1, MA.L2-3.7.5, MA.L2-3.7.6, AC.L2-3.1.5, CM.L2-3.4.8
Editorial implementation guidance published November 20, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.7.2SP 800-171 Rev 3
03.07.0403.07.02 withdrawn; incorporated into03.07.0603.07.02 withdrawn; incorporated intoSP 800-53 Rev 5
MA-2DMA-3DSMA-3(1)DSMA-3(2)DSMA-3(3)SMA-5SHow these were reachedHide how these were reached
- MA-2 · Controlled Maintenance
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MA-2 → 800-53 Rev 5 MA-2
- MA-3 · Maintenance Tools
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MA-3 → 800-53 Rev 5 MA-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3
- MA-3(1) · Maintenance Tools | Inspect Tools
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MA-3 (1) → 800-53 Rev 5 MA-3(1)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(1)
- MA-3(2) · Maintenance Tools | Inspect Media
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MA-3 (2) → 800-53 Rev 5 MA-3(2)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(2)
- MA-3(3) · Maintenance Tools | Prevent Unauthorized Removal
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(3)
- MA-5 · Maintenance Personnel
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.06 → 800-53 Rev 5 MA-5
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (17 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- MA.L2-3.7.2 → 3.7.2“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
NIST SP 800-171 Rev 3 (OSCAL) NIST
- 03.07.02 → 03.07.04“Incorporated into”control 03.07.02 link rel=incorporated_into
- 03.07.02 → 03.07.06“Incorporated into”control 03.07.02 link rel=incorporated_into
- 03.07.04 → MA-3“Source control”control 03.07.04 link rel=reference (MA-03)
- 03.07.04 → MA-3(1)“Source control”control 03.07.04 link rel=reference (MA-03(01))
- 03.07.04 → MA-3(2)“Source control”control 03.07.04 link rel=reference (MA-03(02))
- 03.07.04 → MA-3(3)“Source control”control 03.07.04 link rel=reference (MA-03(03))
- 03.07.06 → MA-5“Source control”control 03.07.06 link rel=reference (MA-05)
NIST SP 800-53 Rev 4 → Rev 5 comparison NIST
- MA-2 → MA-2“Adds parameter Changes control text Changes discussion”sheet "Rev4 Rev5 Compared" row 503
- MA-3 → MA-3“Adds parameter Adds control text Changes discussion”sheet "Rev4 Rev5 Compared" row 506
- MA-3 (1) → MA-3(1)“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 507
- MA-3 (2) → MA-3(2)“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 508
Trace notes
Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.
About this practice
Expert CMMC note
The "personnel" part of 3.7.2 traces to MA-5 (Rev 3 03.07.06). Appendix D lists MA-5 under 3.7.6 only, because it mapped the 3.7.1-3.7.2 basic group jointly.
Relies on: NIST SP 800-171 Rev 2, p.86, Appendix D, Table D-7; NIST SP 800-171 Rev 2, pp.40-41 3.7.2; NIST SP 800-171 Rev 3, pp.53-54 03.07.06
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Control maintenance tools, techniques, mechanisms, and personnel.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You are responsible for maintenance activities on your company ’s machines. To avoid introducing additional vulnerability into the systems you are maintaining, you make sure that all maintenance tools are approved and their usage is monitored and controlled [a,b]. You ensure the tools are kept current and up -to-date [a]. You and your backup are the only people authorized to use these tools and perform system maintenance [d].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): System maintenance policy; procedures addressing system maintenance tools and media; maintenance records; system maintenance tools and associated documentation; maintenance tool inspection records; system security plan; other relevant documents or records
Common mistakes
Approving a maintenance visit without considering the tools and methods used.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/