Crosswalk
CMMC to NIST Crosswalk
Each CMMC practice with the NIST SP 800-171 Rev 2 requirement it is built on, the Rev 3 counterpart, the SP 800-53 Rev 4 and Rev 5 controls behind it and, for Level 3, the SP 800-172 requirement and its Rev 3 successor. Open any number to read it.
Filters2 on
4 practices · Level 1 · AC — Access Control · To 800-53 Rev 5 · Clear
Showing one domain. The whole table, 149 practices in 14 domains on one page, and its downloads are for members.
Free with an account. Create a free account or sign in.
About these relationships
Mappings are the guides' key references and NIST's published relationships; a practice with no mapping yet shows a dash. Every cell comes from an official NIST or DoD table: Rev 3 entries from NIST's change analyses (a withdrawn requirement leads to the requirement NIST says replaces it), Rev 4 controls from SP 800-171 Rev 2 Appendix D, and each Rev 5 control carries the path that reached it.
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Spot an error? Email [email protected] with the practice number and the official document you are reading.
- AC.L1-b.1.iAuthorized Access Control [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-53 Rev 56
AC-2DSAC-2(3)SAC-2(5)SAC-2(13)SAC-3DAC-17DHow these were reachedHide how these were reached
- AC-2 · Account Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(3) · Account Management | Disable Accounts
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(3)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(5) · Account Management | Inactivity Logout
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(5)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-2(13) · Account Management | Disable Accounts for High-risk Individuals
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.01 → 800-53 Rev 5 AC-2(13)NIST: 03.01.01 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.9.2e addressed by (SP 800-171 Rev 3)
- AC-3 · Access Enforcement
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
- AC-17 · Remote Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
- AC-2 · Account Management
- AC.L1-b.1.iiTransaction & Function Control [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-53 Rev 53
AC-2DAC-3DSAC-17DHow these were reachedHide how these were reached
- AC-2 · Account Management
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-2 → 800-53 Rev 5 AC-2
- AC-3 · Access Enforcement
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-3 → 800-53 Rev 5 AC-3
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.02 → 800-53 Rev 5 AC-3NIST: 03.01.02 also: 3.13.3 addressed by
- AC-17 · Remote Access
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 → 800-53 Rev 5 AC-17
- AC-2 · Account Management
- AC.L1-b.1.iiiExternal Connections [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-53 Rev 53
AC-20DSAC-20(1)DSAC-20(2)SHow these were reachedHide how these were reached
- AC-20 · Use of External Systems
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 → 800-53 Rev 5 AC-20
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20NIST: 03.01.20 also: 3.1.21 incorporated into
- AC-20(1) · Use of External Systems | Limits on Authorized Use
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 (1) → 800-53 Rev 5 AC-20(1)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(1)NIST: 03.01.20 also: 3.1.21 incorporated into
- AC-20(2) · Use of External Systems | Portable Storage Devices — Restricted Use
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(2)NIST: 03.01.20 also: 3.1.21 incorporated into
- AC-20 · Use of External Systems
- AC.L1-b.1.ivControl Public Information [FCI Data]
NIST SP 800-171 Rev 21
NIST SP 800-53 Rev 51
AC-22DSHow these were reachedHide how these were reached
- AC-22 · Publicly Accessible Content
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-22 → 800-53 Rev 5 AC-22
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.22 → 800-53 Rev 5 AC-22
- AC-22 · Publicly Accessible Content