Skip to content
Back to System & Information Integrity
CMMC · Rev 2.13L1SI · System & Information Integrity

SI.L1-b.1.xiv

Update Malicious Code Protection [FCI Data]

Requirement

Update malicious code protection mechanisms when new releases are available.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. amalicious code protection mechanisms are updated when new releases are available.

From the CMMC Level 1 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Keep malware protection current: signature and engine updates should install automatically as soon as the vendor releases them, and you should be able to show that every device is up to date. With Microsoft Defender or any modern antivirus this is mostly a matter of leaving automatic updates on and checking the console for devices that have fallen behind. The same practice appears at Level 2 as SI.L2-3.14.4 for CUI.

The minimum for a small organization · Expert CMMC's reading, not official text

Keep malware protection current: updates install when the vendor releases them [a]; writing down how often devices check for them, and being able to show every device is up to date, is the usual way to show it. With modern antivirus this mostly means leaving automatic updates on and checking the console for devices that have fallen behind.

Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.49 SI.L1-b.1.xiv

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeTechnicalUpdate malicious code protection mechanisms when new releases are available.[a]

    You can tell it worked when the console or a per-device report shows each protected device on a current definition version.

    SourceCMMC Assessment Guide Level 1 v2.13objective [a], p.49
    Quoted words
    • “malicious code protection mechanisms are updated when new releases are available”
  2. 2
    Recommended wayTechnicalFor objective [a], have definition, engine and platform updates install as the vendor publishes them, and write down how often devices check for updates. The guide's assessment consideration asks whether there is a defined frequency at which malicious code protection mechanisms must be updated, for example the frequency of automatic updates or manual processes (L1 guide p.50).[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.50 SI.L1-b.1.xiv
  3. 3
    Recommended wayPolicyState in your security policy that definitions and engines update automatically, devices check at least daily, and out-of-date devices are fixed within a set time (for example two business days).[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.49 SI.L1-b.1.xiv
  4. 4
    Recommended wayTechnicalConfigure automatic updates in the antivirus product (for Microsoft Defender, security intelligence updates through Windows Update or Intune with a daily or more frequent check), and allow updates from the vendor's cloud for laptops rarely in the office.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.49 SI.L1-b.1.xiv
  5. 5
    Recommended wayProcessCheck the console on a schedule you set (weekly or monthly is common) for out-of-date definitions, devices that have not checked in and old engine or platform versions, and fix them.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 1 v2.13p.49 SI.L1-b.1.xiv

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

The detail for 3 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Microsoft Defender Antivirus (built into Windows)Endpoint anti-malwareFree
Microsoft Defender for Business / IntuneCentral update reportingPaid
CrowdStrike Falcon / SentinelOne SingularityEDRPaid

16 dated vendor facts and notes on 3 products for this practice: what each assumes, what it does not cover and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: SI.L1-b.1.xiii, SI.L1-b.1.xv, SI.L2-3.14.4

Editorial implementation guidance published November 20, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.14.4

SP 800-171 Rev 3

03.14.0203.14.04 withdrawn; incorporated into

SP 800-53 Rev 4

SI-3

SP 800-53 Rev 5

SI-3DS
How these were reached
  • SI-3 · Malicious Code Protection
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SI-3 → 800-53 Rev 5 SI-3
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.14.02 → 800-53 Rev 5 SI-3NIST: 03.14.02 also: 3.14.5 addressed by

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (6 links from 5 official documents)

CMMC Assessment Guide Level 1 v2.13 DoD CIO

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.14.4 → 03.14.04“Withdrawn”sheet "Change Analysis 800-171 R2-R3" row 118

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.14.04 → 03.14.02“Incorporated into”control 03.14.04 link rel=incorporated_into
  • 03.14.02 → SI-3“Source control”control 03.14.02 link rel=reference (SI-03)

NIST SP 800-171 Rev 2 NIST

  • 3.14.4 → SI-3“Appendix D mapping”p.96 Table D-14

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • SI-3 → SI-3“Adds parameter Changes parameter Changes discussion”sheet "Rev4 Rev5 Compared" row 1055

Further discussion

Malware changes on an hourly or daily basis, and it is important to update detection and protection mechanisms frequently to maintain the effectiveness of the protection. Example You have installed anti-malware software to protect a computer that stores FCI from malicious code. Knowing that malware evolves rapidly, you configure the software to automatically check for malware definition updates every day and update as needed [a]. Potential Assessment Considerations • Is there a defined frequency at which malicious code protection mechanisms must be updated (e.g., frequency of automatic updates or manual processes) [a]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Keep malicious-code protection mechanisms current when updates are available.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You have installed anti- malware software to protect a computer that stores FCI from malicious code. Knowing that malware evolves rapidly, you configure the software to automatically check for malware definition updates every day and update as needed [a].

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): System and information integrity policy; configuration management policy and procedures; procedures addressing malicious code protection; malicious code protection mechanisms; records of malicious code protection updates; system security plan; system design documentation; system configuration settings and associated documentation; scan results from malicious code protection mechanisms; record of actions initiated by malicious code protection mechanisms in response to malicious code detection; system audit logs and records; other relevant documents or records

Common mistakes

Assuming installed antivirus automatically has current software, signatures, and detection information.

Track this in a workspace

The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Source: DoD CIO · https://dodcio.defense.gov/CMMC/