Skip to content
Back to System & Communications Protection
CMMC · Rev 2.13L3SC · System & Communications Protection

SC.L3-3.13.4e

Isolation

Requirement

Employ physical isolation techniques or logical isolation techniques or both in organizational systems and system components.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. ODP1One or more of the following is/are selected: physical isolation techniques; logical isolation techniques;
  2. ODP2Physical isolation techniques are defined (if selected);
  3. ODP3Logical isolation techniques are defined (if selected);
  4. aPhysical isolation techniques or logical isolation techniques or both are employed in organizational systems and system components.

From the CMMC Level 3 Assessment Guide v2.13 · publisher approved 2026-11-08.

How to implement

Level 3 adds deliberate isolation on top of the Level 2 boundary, segmentation and deny-by-default controls: choose physical isolation techniques (separate hardware, networks or air-gapped systems), logical isolation techniques (internal firewalls, microsegmentation, separate cloud tenants, subscriptions or virtual networks, virtualization) or both, document which ones you use where, and apply them so that an attacker who gets into one part of the environment cannot move freely to CUI or to your security and management systems. This assumes SC.L2-3.13.1, 3.13.5 and 3.13.6 are already in place; mature microsegmentation and independent isolation testing usually mean buying products or services.

The minimum for a small organization · Expert CMMC's reading, not official text

Choose physical isolation, logical isolation or both [ODP1], define the techniques you use [ODP2] [ODP3], and apply them to your systems and components [a]. For a small Level 3 contractor that is usually a separate CUI environment behind its own firewall with deny-by-default rules between security domains, an isolated management plane and backups, and host firewalls that stop lateral movement.

Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomePolicySelect physical isolation techniques, logical isolation techniques or both, and define the techniques selected.[ODP1][ODP2][ODP3]
    SourceCMMC Assessment Guide Level 3 v2.13objectives [ODP1], [ODP2] and [ODP3], p.74
    Quoted words
    • “One or more of the following is/are selected: physical isolation techniques; logical isolation techniques”
    • “Physical isolation techniques are defined (if selected)”
    • “Logical isolation techniques are defined (if selected)”
  2. 2
    Recommended wayPolicyFor objectives [ODP1] to [ODP3], identify the systems or enclaves that need isolating, and document or reference in the SSP the techniques selected and where each is used. The guide's further discussion says organizations must identify the systems or enclaves that need to be isolated, then design and implement the isolation, and that the resulting isolation solutions are documented or referenced in the SSP (L3 guide p.76).[ODP1][ODP2][ODP3]

    You can tell it worked when the SSP names each isolated system or enclave and the isolation technique applied to it.

    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.76 SC.L3-3.13.4e
  3. 3
    Required outcomeTechnicalEmploy the selected physical or logical isolation techniques, or both, in organizational systems and system components.[a]

    You can tell it worked when connectivity tests between security domains succeed only for documented flows.

    SourceCMMC Assessment Guide Level 3 v2.13objective [a], p.74
    Quoted words
    • “Physical isolation techniques or logical isolation techniques or both are employed in organizational systems and system components”
  4. 4
    Recommended wayPolicyDefine in the SSP the physical and logical isolation techniques the organization employs and for which systems and components: for example, physically separate networks or standalone workstations for the most sensitive program data, an internal firewall between the CUI enclave and corporate IT, separate cloud tenants or subscriptions for CUI workloads, a separate management network, and host-based segmentation inside the enclave.[ODP1][ODP2][ODP3]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e
  5. 5
    Recommended wayTechnicalIsolate the CUI environment and the Level 3 scope from the rest of the business with a dedicated internal firewall or separate infrastructure enforcing deny-by-default between domains, and use secure, controlled transfer methods for any information that must cross between them (see AC.L3-3.1.3e).[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e
  6. 6
    Recommended wayTechnicalIsolate the systems an attacker most wants: the administrative plane (management VLAN, privileged access workstations or jump hosts, separate admin identities), security tooling (log platform, EDR console), and backups (immutable or offline copies that the production domain cannot alter). Isolate OT, IoT and specialized assets that cannot be hardened.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e
  7. 7
    Recommended wayTechnicalLimit lateral movement inside the enclave: host firewall policies or a microsegmentation product so workstations cannot connect to each other and servers accept only the flows they need; separate virtual networks and security groups for different workload tiers in the cloud; separate hypervisor hosts or clusters where workloads of different sensitivity would otherwise share hardware.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e
  8. 8
    Recommended wayProcessVerify the isolation works: test connectivity between segments after every significant change and at least annually, include isolation in penetration testing (CA.L3-3.12.1e), and review isolation rules on a schedule. Record findings and remediation.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 3 v2.13p.74 SC.L3-3.13.4e

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Internal segmentation firewall (Fortinet FortiGate, Palo Alto Networks)Logical isolation between domainsPaid
Windows Defender Firewall via Intune or Group PolicyHost-based segmentationFree
IllumioMicrosegmentationEnterprise pricing
Zero NetworksAutomated microsegmentationPaid
Standalone or air-gapped workstationPhysical isolationPaid
Third-party penetration testIsolation verificationPaid

12 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: SC.L2-3.13.1, SC.L2-3.13.5, SC.L2-3.13.6, SC.L2-3.13.3, AC.L3-3.1.3e, CA.L3-3.12.1e

Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-172 (Feb 2021)

3.13.4e

SP 800-172 Rev 3

03.13.04E

—

SP 800-53 Rev 5

SC-7CSC-7(13)CSC-7(21)CSSC-7(22)CSC-25C
How these were reached
  • SC-7 · Boundary Protection
    • C SP 800-172 (Feb 2021) Appendix C
  • SC-7(13) · Boundary Protection | Isolation of Security Tools, Mechanisms, and Support Components
    • C SP 800-172 (Feb 2021) Appendix C
  • SC-7(21) · Boundary Protection | Isolation of System Components
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-172 Rev 3 03.13.04E → 800-53 Rev 5 SC-7(21)
    • C SP 800-172 (Feb 2021) Appendix C
  • SC-7(22) · Boundary Protection | Separate Subnets for Connecting to Different Security Domains
    • C SP 800-172 (Feb 2021) Appendix C
  • SC-25 · Thin Nodes
    • C SP 800-172 (Feb 2021) Appendix C

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (8 links from 4 official documents)

32 CFR 170.14 Office of the Federal Register / GPO

NIST SP 800-172 → Rev 3 change analysis NIST

  • 3.13.4e → 03.13.04E“Significant Change; New or Changed ODP”sheet "Change Analysis SP 800-172-R3" row 76

NIST SP 800-172 (Feb 2021) NIST

NIST SP 800-172 Rev 3 (OSCAL) NIST

  • 03.13.04E → SC-7(21)“Source control”control 03.13.04E link rel=external_reference (SC-07(21))

Trace notes

Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.

About this practice

  • Expert CMMC note

    SC-25 is listed in 800-172 App. C because thin/zero clients are one isolation option in the 3.13.4e discussion. It is not required to meet 3.13.4e; 800-172r3 made it a separate requirement (03.13.11E).

    Relies on: NIST SP 800-172 (Feb 2021), p.76, Appendix C, Table C-13; NIST SP 800-172 (Feb 2021), pp.37-38 3.13.4e; NIST SP 800-172 Rev 3, pp.69-70 03.13.11E

About SP 800-172 (Feb 2021) 3.13.4e

  • Expert CMMC note

    See also SP 800-172 Rev 3 03.13.09E. Related by shared source control SC-7(13), not a NIST successor link: Rev 3 split 3.13.4e.

    Relies on: NIST SP 800-172 (Feb 2021), p.76, Appendix C, Table C-13; NIST SP 800-172 Rev 3, pp.68-69 03.13.09E

  • Expert CMMC note

    See also SP 800-172 Rev 3 03.13.10E. Related by shared source control SC-7(22), not a NIST successor link: Rev 3 split 3.13.4e.

    Relies on: NIST SP 800-172 (Feb 2021), p.76, Appendix C, Table C-13; NIST SP 800-172 Rev 3, p.69 03.13.10E

  • Expert CMMC note

    See also SP 800-172 Rev 3 03.13.11E. Related by shared source control SC-25, not a NIST successor link: Rev 3 split 3.13.4e.

    Relies on: NIST SP 800-172 (Feb 2021), p.76, Appendix C, Table C-13; NIST SP 800-172 Rev 3, pp.69-70 03.13.11E

Further discussion

For this requirement, organizations must identify the systems or enclaves that need to be isolated, then design and implement the isolation. The resulting isolation solutions are documented or referenced in the SSP. Documentation will be dependent on the design selected and may include a high-level diagram, but specific details that may change on some frequency would be omitted. During an assessment, providing details such as subnet and VLAN implementation identifiers, internal boundary protection hardware and software, interface device functionality, and system configuration and Access Control List (ACL) settings will be useful. Example You are responsible for information security in your organization, which holds and processes CUI. You have decided to isolate the systems processing CUI by limiting all communications in and out that enclave with cross-domain interface devices that implement access control [a]. Your security team has identified all the systems containing such CUI, documented network design details, developed network diagrams showing access control points, documented the logic for the access control enforcement decisions, described the interface and protocol to the identification and authentication mechanisms, and documented all details associated with the ACLs, including review, updates, and credential revocation procedures. Potential Assessment Considerations • Has the organization clearly identified where they use physical, logical, or both isolation techniques [a]? • Can the organization describe the isolation techniques they have employed [a]? • Has the organization deployed subnetting, internal firewalls, and VLANs to control packet flow between internal segments [a]? • Does the organization employ metadata to inform isolation techniques [a]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Separate systems and components using physical isolation, logical isolation or both.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You are responsible for information security in your organization, which holds and processes CUI. You have decided to isolate the systems processing CUI by limiting all communications in and out that enclave with cross-domain interface devices that implement access control [a]. Your security team has identified all the systems containing such CUI, documented network design details, developed network diagrams showing access control points, documented the logic for the access control enforcement decisions, described the interface and protocol to the identification and authentication mechanisms, and documented all details associated with the ACLs, including review, updates, and credential revocation procedures.

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): System and communications protection policy; procedures addressing boundary protection; system design documentation; procedures addressing the use of thin nodes; list of key internal boundaries of the system; security plan; boundary protection hardware and software; system configuration settings and associated documentation; enterprise architecture documentation; system architecture; security architecture documentation; system audit records; system component inventory; list of security tools and support components to be isolated from other system components; other relevant documents or records

Common mistakes

Relying on VLANs without access controls between them and calling that isolation.

Track this in a workspace

The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Source: DoD CIO · https://dodcio.defense.gov/CMMC/