SC.L2-3.13.5
Public-Access System Separation [CUI Data]
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- apublicly accessible system components are identified; and
- bsubnetworks for publicly accessible system components are physically or logically separated from internal networks.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Identify every system component the public can reach (websites, customer or supplier portals, file-transfer sites, VPN and remote desktop gateways, publicly reachable cloud services) and keep each on a subnetwork that is physically or logically separated from the internal network holding CUI, with connections from that subnetwork into internal systems blocked by default. The simplest answer for a small contractor is to host public services entirely outside the CUI environment and document that in the SSP.
The minimum for a small organization · Expert CMMC's reading, not official text
List every part of your systems the public can reach [a], such as websites, portals, file-transfer sites and remote access gateways, and keep each on a network physically or logically separate from your internal networks [b]. Hosting the public website with an outside provider, apart from the CUI environment, is the simplest way.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessIdentify publicly accessible system components.[a]
You can tell it worked when an external scan of your public addresses finds nothing missing from the inventory.
SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.229Quoted words
- “publicly accessible system components are identified”
- 2Required outcomeTechnicalSeparate the subnetworks for publicly accessible components physically or logically from internal networks.[b]
You can tell it worked when no public component sits on an internal network, and traffic from public components to internal networks is denied by default.
SourceCMMC Assessment Guide Level 2 v2.13objective [b], p.229Quoted words
- “subnetworks for publicly accessible system components are physically or logically separated from internal networks”
- 3Recommended wayProcessInventory every publicly accessible component: websites and forms, portals used by customers or suppliers, external file-sharing or managed file transfer sites used to exchange CUI, VPN and remote desktop gateways, and any port forwards. Verify with an external scan of your public IP ranges and a review of your DNS records [a].[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
- 4Recommended wayPolicyRecord in the SSP which public components exist, where each is hosted, and the rule that public services are never placed on internal CUI network segments; new public services require approval and an SSP update.[a][b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
- 5Recommended wayTechnicalPlace self-hosted public services in a DMZ on a dedicated firewall interface or VLAN with filtering: inbound only the published service ports, all DMZ-to-internal traffic denied by default, and only specific documented connections (for example an internal admin host to the DMZ server over SSH) allowed in the other direction [b].[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
- 6Recommended wayTechnicalFor cloud-hosted public services, use a separate subscription, account or tenant from the CUI environment, separate admin credentials, and no network peering or site-to-site VPN into the enclave. A portal that external parties use to exchange CUI must pass Before CUI goes into a cloud service (FedRAMP Moderate or equivalent) and is itself documented as part of the boundary.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
- 7Recommended wayProcessRe-scan externally and review DMZ rules at least quarterly and on every change to public services; reconcile any unexpected open port immediately.[a][b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Publicly accessible component inventory[a]
Network diagram with DMZ or external hosting[b]
Separation evidence for cloud-hosted public services[b]
The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
10 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- A company website or customer portal hosted on a virtual machine on the same host or VLAN as CUI servers.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.230 SC.L2-3.13.5
- A file-transfer portal for exchanging CUI with primes that has not passed Before CUI goes into a cloud service (FedRAMP Moderate or equivalent).Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
- DMZ servers allowed to write to an internal share or database 'so the web form works'.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.230 SC.L2-3.13.5
- Forgotten public components: old test sites, camera recorders, remote management pages on printers or UPS units.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.230 SC.L2-3.13.5
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: SC.L2-3.13.1, SC.L2-3.13.6, AC.L2-3.1.22, SC.L1-b.1.xi, RA.L2-3.11.2
Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.13.5SP 800-171 Rev 3
03.13.0103.13.05 withdrawn; incorporated intoSP 800-53 Rev 4
SC-7SP 800-53 Rev 5
SC-7DSHow these were reachedHide how these were reached
- SC-7 · Boundary Protection
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (6 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- SC.L2-3.13.5 → 3.13.5“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Separate publicly accessible system components from internal networks.
Implementation example
Example from the source assessment guide (not a mandatory implementation): The head of recruiting at your company wants to launch a website to post job openings and allow the public to download an application form [a]. After some discussion, your team realizes it needs to use a firewall to create a perimeter network to do this [b]. You host the server separately from the company’s internal network and make sure the network on which it resides is isolated with the proper firewall rules [b].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): System and commun ications protection policy; procedures addressing boundary protection; system security plan; list of key internal boundaries of the system; system design documentation; boundary protection hardware and software; system configuration settings and associated documentation; enterprise security architecture documentation; system audit logs and records; other relevant documents or records
Common mistakes
Allowing public-facing services unrestricted access to internal systems.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/