SC.L2-3.13.5

Public-Access System Separation [CUI Data]

Requirement

Implement subnetworks for publicly accessible system components that are physically or logically separated from internal networks.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. apublicly accessible system components are identified; and
  2. bsubnetworks for publicly accessible system components are physically or logically separated from internal networks.

From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Identify every system component the public can reach (websites, customer or supplier portals, file-transfer sites, VPN and remote desktop gateways, publicly reachable cloud services) and keep each on a subnetwork that is physically or logically separated from the internal network holding CUI, with connections from that subnetwork into internal systems blocked by default. The simplest answer for a small contractor is to host public services entirely outside the CUI environment and document that in the SSP.

The minimum for a small organization · Expert CMMC's reading, not official text

List every part of your systems the public can reach [a], such as websites, portals, file-transfer sites and remote access gateways, and keep each on a network physically or logically separate from your internal networks [b]. Hosting the public website with an outside provider, apart from the CUI environment, is the simplest way.

Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeProcessIdentify publicly accessible system components.[a]

    You can tell it worked when an external scan of your public addresses finds nothing missing from the inventory.

    SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.229
    Quoted words
    • “publicly accessible system components are identified”
  2. 2
    Required outcomeTechnicalSeparate the subnetworks for publicly accessible components physically or logically from internal networks.[b]

    You can tell it worked when no public component sits on an internal network, and traffic from public components to internal networks is denied by default.

    SourceCMMC Assessment Guide Level 2 v2.13objective [b], p.229
    Quoted words
    • “subnetworks for publicly accessible system components are physically or logically separated from internal networks”
  3. 3
    Recommended wayProcessInventory every publicly accessible component: websites and forms, portals used by customers or suppliers, external file-sharing or managed file transfer sites used to exchange CUI, VPN and remote desktop gateways, and any port forwards. Verify with an external scan of your public IP ranges and a review of your DNS records [a].[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
  4. 4
    Recommended wayPolicyRecord in the SSP which public components exist, where each is hosted, and the rule that public services are never placed on internal CUI network segments; new public services require approval and an SSP update.[a][b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
  5. 5
    Recommended wayTechnicalPlace self-hosted public services in a DMZ on a dedicated firewall interface or VLAN with filtering: inbound only the published service ports, all DMZ-to-internal traffic denied by default, and only specific documented connections (for example an internal admin host to the DMZ server over SSH) allowed in the other direction [b].[b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
  6. 6
    Recommended wayTechnicalFor cloud-hosted public services, use a separate subscription, account or tenant from the CUI environment, separate admin credentials, and no network peering or site-to-site VPN into the enclave. A portal that external parties use to exchange CUI must pass Before CUI goes into a cloud service (FedRAMP Moderate or equivalent) and is itself documented as part of the boundary.[b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5
  7. 7
    Recommended wayProcessRe-scan externally and review DMZ rules at least quarterly and on every change to public services; reconcile any unexpected open port immediately.[a][b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.229 SC.L2-3.13.5

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

External managed website hostingOff-network hostingPaid
Fortinet FortiGateFirewall with DMZPaid
OPNsense or pfSense CEOpen-source firewallFree
KiteworksSecure file exchangeEnterprise pricing
CISA Cyber Hygiene Vulnerability ScanningExternal exposure checkFree
NmapExternal exposure checkFree

10 dated vendor facts and notes on 6 products for this practice: what each assumes, what it does not cover and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: SC.L2-3.13.1, SC.L2-3.13.6, AC.L2-3.1.22, SC.L1-b.1.xi, RA.L2-3.11.2

Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.13.5

SP 800-171 Rev 3

03.13.0103.13.05 withdrawn; incorporated into

SP 800-53 Rev 4

SC-7

SP 800-53 Rev 5

SC-7DS
How these were reached
  • SC-7 · Boundary Protection
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 SC-7 → 800-53 Rev 5 SC-7
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.13.01 → 800-53 Rev 5 SC-7NIST: 03.13.01 also: SP 800-172 (Feb 2021) 3.14.3e addressed by (SP 800-171 Rev 3)

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (6 links from 5 official documents)

32 CFR Part 170 Office of the Federal Register / GPO

  • SC.L2-3.13.5 → 3.13.5“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.13.5 → 03.13.05“Withdrawn”sheet "Change Analysis 800-171 R2-R3" row 103

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.13.05 → 03.13.01“Incorporated into”control 03.13.05 link rel=incorporated_into
  • 03.13.01 → SC-7“Source control”control 03.13.01 link rel=reference (SC-07)

NIST SP 800-171 Rev 2 NIST

  • 3.13.5 → SC-7“Appendix D mapping”p.93 Table D-13

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • SC-7 → SC-7“Changes control text”sheet "Rev4 Rev5 Compared" row 903

Further discussion

Separate the publicly accessible systems from the internal systems that need to be protected. Do not place internal systems on the same network as the publicly accessible systems and block access by default from DMZ networks to internal networks. One method of accomplishing this is to create a DMZ network, which enhances security by providing public access to a specific set of resources while preventing connections from those resources to the rest of the IT environment. Some OSAs achieve a similar result through the use of a cloud computing environment that is separated from the rest of the company’s infrastructure. Example The head of recruiting at your company wants to launch a website to post job openings and allow the public to download an application form [a]. After some discussion, your team realizes it needs to use a firewall to create a perimeter network to do this [b]. You host the server separately from the company’s internal network and make sure the network on which it resides is isolated with the proper firewall rules [b]. Potential Assessment Considerations • Are any system components reachable by the public (e.g., internet-facing web servers, VPN gateways, publicly accessible cloud services) [a]? • Are publicly accessible system components on physically or logically separated subnetworks (e.g., isolated subnetworks using separate, dedicated VLAN segments such as DMZs) [b]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Separate publicly accessible system components from internal networks.

Implementation example

Example from the source assessment guide (not a mandatory implementation): The head of recruiting at your company wants to launch a website to post job openings and allow the public to download an application form [a]. After some discussion, your team realizes it needs to use a firewall to create a perimeter network to do this [b]. You host the server separately from the company’s internal network and make sure the network on which it resides is isolated with the proper firewall rules [b].

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): System and commun ications protection policy; procedures addressing boundary protection; system security plan; list of key internal boundaries of the system; system design documentation; boundary protection hardware and software; system configuration settings and associated documentation; enterprise security architecture documentation; system audit logs and records; other relevant documents or records

Common mistakes

Allowing public-facing services unrestricted access to internal systems.