Skip to content
Back to Level 2
CMMC · Rev 2.13L2PS · Personnel Security

PS.L2-3.9.1

Screen Individuals

Requirement

Screen individuals prior to authorizing access to organizational systems containing CUI.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. aindividuals are screened prior to authorizing access to organizational systems containing CUI.

From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Before anyone is given access to systems that hold CUI, complete the screening you have defined for their role, such as identity verification, a criminal background check and employment verification, and keep a record showing screening finished before access was granted. This covers employees, contractors and temps, and, through your contract, MSP or other service-provider staff who can reach the CUI environment. Work with HR and employment counsel so the checks follow the Fair Credit Reporting Act and state and local hiring laws.

The minimum for a small organization · Expert CMMC's reading, not official text

Screen people before they get access to systems that hold CUI [a]. Grant access only after the screening is complete, including for MSP and contractor staff; deciding the screening each role needs and recording when it was done are the usual way.

Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeProcessScreen individuals before authorizing access to organizational systems containing CUI.[a]

    You can tell it worked when for every member of the CUI access group, the screening log shows a completed screening dated before access was granted.

    SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.183
    Quoted words
    • “individuals are screened prior to authorizing access to organizational systems containing CUI”
  2. 2
    Recommended wayPolicyWrite a personnel screening policy: which roles have CUI access, the screening required for each (for example identity verification and criminal history for all CUI users; added checks for administrators or finance roles where lawful), how results are judged, what happens for people hired before the policy, and when rescreening is triggered (move into a privileged role, a break in employment). Where your contract or the export classification of the data requires it (for example ITAR- or EAR-controlled CUI), also confirm U.S. person status, which is separate from background screening.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1
  3. 3
    Recommended wayProcessUse an FCRA-compliant background screening provider with the required written disclosure and authorization, and adverse-action steps if a result may lead to a decision. HR records completion date and outcome (cleared / not cleared) in the HR system or a restricted screening log; detailed reports stay in confidential HR files, not with IT.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1and15 U.S.C. 1681b (FCRA)p.2 1681b(b)(2) and (b)(3)and15 U.S.C. 1681m (FCRA)p.1 1681m(a)
  4. 4
    Recommended wayProcessGate access on screening: the onboarding or access-request ticket for the CUI group includes a required 'screening complete' confirmation from HR, and IT does not add the person to CUI groups, issue enclave devices or grant VPN until it is recorded.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1
  5. 5
    Recommended wayPolicyCover non-employees: contract clauses requiring MSPs, staffing agencies and subcontractors with access to screen their personnel to your criteria, and a written attestation or roster for each named individual before their accounts are created. A current DoD security clearance verified through your facility security officer can satisfy screening if your policy says so.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1
  6. 6
    Recommended wayProcessQuarterly, compare CUI group membership and privileged accounts against the screening log; anyone without a recorded screening is escalated and their access suspended until resolved. Record the review.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.183 PS.L2-3.9.1

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

Personnel screening policy and position criteria[a]

Screening log[a]

Access-request tickets showing screening confirmation[a]

Service-provider screening clauses and attestations[a]

Quarterly screening reconciliation[a]

The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

CheckrBackground screeningPaid
GoodHireBackground screeningPaid
HireRight / First Advantage (Sterling)Enterprise background screeningEnterprise pricing
HR system (BambooHR, Rippling, Gusto) screening fieldsHR recordsPaid
Restricted spreadsheet screening logRecordsFree

Notes on 5 products for this practice: why each matters here, what it assumes and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: PS.L2-3.9.2, IA.L2-3.5.2, AC.L2-3.1.1, PS.L3-3.9.2e

Editorial implementation guidance published November 20, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.9.1

SP 800-171 Rev 3

03.09.01

SP 800-53 Rev 4

PS-3PS-4PS-5

SP 800-53 Rev 5

PS-3DSPS-4DPS-5D
How these were reached
  • PS-3 · Personnel Screening
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PS-3 → 800-53 Rev 5 PS-3
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.09.01 → 800-53 Rev 5 PS-3NIST: 03.09.01 also: SP 800-172 (Feb 2021) 3.9.1e, 3.9.2e addressed by (SP 800-171 Rev 3)
  • PS-4 · Personnel Termination
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PS-4 → 800-53 Rev 5 PS-4
  • PS-5 · Personnel Transfer
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 PS-5 → 800-53 Rev 5 PS-5

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (9 links from 5 official documents)

32 CFR Part 170 Office of the Federal Register / GPO

  • PS.L2-3.9.1 → 3.9.1“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.9.1 → 03.09.01“Minor Change”sheet "Change Analysis 800-171 R2-R3" row 80

NIST SP 800-171 Rev 2 NIST

  • 3.9.1 → PS-3“Appendix D mapping”p.89 Table D-9
  • 3.9.1 → PS-4“Appendix D mapping”p.89 Table D-9
  • 3.9.1 → PS-5“Appendix D mapping”p.89 Table D-9

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • PS-3 → PS-3“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 677
  • PS-4 → PS-4“Changes control text Removes parameter”sheet "Rev4 Rev5 Compared" row 682
  • PS-5 → PS-5“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 685

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.09.01 → PS-3“Source control”control 03.09.01 link rel=reference (PS-03)

Trace notes

Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.

About this practice

  • Expert CMMC note

    NIST SP 800-171 Rev 2 Appendix D maps 3.9.1 and 3.9.2 jointly to PS-3, PS-4, PS-5. PS-3 (screening) supports 3.9.1; PS-4/PS-5 (termination/transfer) support 3.9.2.

    Relies on: NIST SP 800-171 Rev 2, Appendix D, Table D-9

About SP 800-171 Rev 2 3.9.1

  • Expert CMMC note3.9.1 ↔ PS-4 (SP 800-53 Rev 4)

    NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.9.1 and 3.9.2 jointly to PS-3, PS-4, PS-5. PS-4 mainly supports 3.9.2, not 3.9.1 specifically.

    Relies on: NIST SP 800-171 Rev 2, p.89, Appendix D, Table D-9

  • Expert CMMC note3.9.1 ↔ PS-5 (SP 800-53 Rev 4)

    NIST SP 800-171 Rev 2 Appendix D maps basic requirements 3.9.1 and 3.9.2 jointly to PS-3, PS-4, PS-5. PS-5 mainly supports 3.9.2, not 3.9.1 specifically.

    Relies on: NIST SP 800-171 Rev 2, p.89, Appendix D, Table D-9

Further discussion

Ensure all employees who need access to CUI undergo organization-defined screening before being granted access. Base the types of screening on the requirements for a given position and role. The effective screening of personnel provided by this requirement, PS.L2-3.9.1, improves upon the effectiveness of authentication performed in IA.L2-3.5.2. Example You are in charge of security at your organization. You complete standard criminal background and credit checks of all individuals you hire before they can access CUI [a]. Your screening program follows appropriate laws, policies, regulations, and criteria for the level of access required for each position. Potential Assessment Considerations • Are appropriate background checks completed prior granting access to organizational systems containing CUI [a]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Screen people before authorizing their access to systems containing controlled information.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You are in charge of security at your organization. You complete standard criminal background and credit checks of all individuals you hire before they can access CUI [a]. Your screening program follows appropriate laws, policies, regulations, and criteria for the level of access required for each position.

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): Personnel security policy; procedures addressing personnel screening; records of screened personnel; system security plan; other relevant documents or records

Common mistakes

Completing screening only after system access has already been granted.

Track this in a workspace

The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Source: DoD CIO · https://dodcio.defense.gov/CMMC/