Skip to content
Back to Level 2
CMMC · Rev 2.13L2MA · Maintenance

MA.L2-3.7.4

Media Inspection

Requirement

Check media containing diagnostic and test programs for malicious code before the media are used in organizational systems.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. amedia containing diagnostic and test programs are checked for malicious code before being used in organizational systems that process, store, or transmit CUI.

From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Any diagnostic or test program that a vendor, MSP or your own staff brings in (a USB stick of utilities, a downloaded support tool, a firmware updater) must be scanned for malicious code before it runs on a system that handles CUI. Treat it like any other downloaded file: scan it with up-to-date anti-malware and record that you did; where the vendor publishes a hash or digital signature, check that too.

The minimum for a small organization · Expert CMMC's reading, not official text

Before a diagnostic or test program touches a system that handles CUI, check it and the media it came on for malicious code [a]. Scanning it with your anti-malware tool and recording the check is the usual way; where the vendor publishes a hash or signature, comparing it as well confirms the file is the vendor's.

Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeProcessCheck media containing diagnostic and test programs for malicious code before they are used in systems that process, store or transmit CUI.[a]

    You can tell it worked when every diagnostic or test program used on a system that handles CUI, and the media it came on, has a recorded malicious-code scan made before use; a hash or signature match on its own is not a check for malicious code.

    SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.158
    Quoted words
    • “media containing diagnostic and test programs are checked for malicious code before being used in organizational systems that process, store, or transmit CUI”
  2. 2
    Recommended wayPolicyAdd a rule to the maintenance policy: diagnostic and test software and the media it arrives on (USB drives, downloads, vendor-supplied laptops' tools, firmware images) are scanned and verified before use on CUI systems; unscanned media may not be connected.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  3. 3
    Recommended wayTechnicalTurn on what the endpoint protection product (Microsoft Defender, CrowdStrike, SentinelOne) offers for removable media and downloads (real-time protection, removable drives in scans, and a scan on insertion where your product documents one), and keep its signatures current; an on-demand scan of the tool, with its result recorded, is still the check before use.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  4. 4
    Recommended wayProcessFor tools downloaded from a vendor, get the expected hash or confirm the code-signing certificate from the vendor's official site, then compare (Get-FileHash in PowerShell or shasum on macOS; Sigcheck or the file's Digital Signatures tab for signatures) before running.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  5. 5
    Recommended wayTechnicalOptionally set up a dedicated scanning station (a standalone, updated machine or a USB-sanitizing kiosk) where vendor media is checked before it touches the CUI network.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  6. 6
    Recommended wayProcessRecord each check in the maintenance ticket: tool name and version, source, scan result, hash match, who checked and the date.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

Maintenance tool and media inspection procedure[a]

Anti-malware removable-media and real-time scanning configuration[a]

Also supports 5 other practices: keep it once

See an example

Inspection records for diagnostic tools[a]

The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Microsoft Defender AntivirusAnti-malwareFree
CrowdStrike Falcon / SentinelOneEndpoint detection and responsePaid
OPSWAT MetaDefender KioskMedia scanning stationEnterprise pricing
CIRCLeanUSB sanitizing stationFree
Get-FileHash, shasum and Sysinternals SigcheckHash and signature verificationFree

5 dated vendor facts and notes on 5 products for this practice: what each assumes, what it does not cover and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

  • Vendor technicians plugging in their own USB stick of tools without anyone scanning it.
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  • Uploading a vendor tool or a file containing CUI to a public multi-scanner site; anything uploaded there may be shared with other users. Upload only hashes, or only files you know contain no sensitive data.
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4
  • Checking downloads but not firmware images, which also run with high privilege.
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.159 MA.L2-3.7.4
  • No record, so the check cannot be shown.
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.158 MA.L2-3.7.4

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: SI.L2-3.14.2, SI.L2-3.14.4, MP.L2-3.8.7, MA.L2-3.7.2

Editorial implementation guidance published November 20, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.7.4

SP 800-171 Rev 3

03.07.04

SP 800-53 Rev 4

MA-3 (2)

SP 800-53 Rev 5

MA-3SMA-3(1)SMA-3(2)DSMA-3(3)S
How these were reached
  • MA-3 · Maintenance Tools
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3NIST: 03.07.04 also: 3.7.2 incorporated into
  • MA-3(1) · Maintenance Tools | Inspect Tools
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(1)NIST: 03.07.04 also: 3.7.2 incorporated into
  • MA-3(2) · Maintenance Tools | Inspect Media
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 MA-3 (2) → 800-53 Rev 5 MA-3(2)
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(2)NIST: 03.07.04 also: 3.7.2 incorporated into
  • MA-3(3) · Maintenance Tools | Prevent Unauthorized Removal
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.07.04 → 800-53 Rev 5 MA-3(3)NIST: 03.07.04 also: 3.7.2 incorporated into

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (8 links from 5 official documents)

32 CFR Part 170 Office of the Federal Register / GPO

  • MA.L2-3.7.4 → 3.7.4“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.7.4 → 03.07.04“Significant Change”sheet "Change Analysis 800-171 R2-R3" row 68

NIST SP 800-171 Rev 2 NIST

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.07.04 → MA-3“Source control”control 03.07.04 link rel=reference (MA-03)
  • 03.07.04 → MA-3(1)“Source control”control 03.07.04 link rel=reference (MA-03(01))
  • 03.07.04 → MA-3(2)“Source control”control 03.07.04 link rel=reference (MA-03(02))
  • 03.07.04 → MA-3(3)“Source control”control 03.07.04 link rel=reference (MA-03(03))

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • MA-3 (2) → MA-3(2)“More than editorial or administrative change? N”sheet "Rev4 Rev5 Compared" row 508

Further discussion

As part of troubleshooting, a vendor may provide a diagnostic application to install on a system. As this is executable code, there is a chance that the file is corrupt or infected with malicious code. Implement procedures to scan any files prior to installation. The same level of scrutiny must be made as with any file a staff member may download. This requirement, MA.L2-3.7.4, extends both SI.L2-3.14.2 and SI.L2-3.14.4. SI.L2-3.14.2 and SI.L2-3.14.4 require the implementation and updating of mechanisms to protect systems from malicious code, and MA.L2-3.7.4 extends this requirement to diagnostic and testing tools. Example You have recently been experiencing performance issues on one of your servers. After troubleshooting for much of the morning, the vendor has asked to install a utility that will collect more data from the server. The file is stored on the vendor’s FTP server. The support technician gives you the FTP site so you can anonymously download the utility file. You also ask him for a hash of the utility file. As you download the file to your local computer, you realize it is compressed. You unzip the file and perform a manual antivirus scan, which reports no issues [a]. To verify the utility file has not been altered, you run an application to see that the hash from the vendor matches. Potential Assessment Considerations • Are media containing diagnostic and test programs (e.g., downloaded or copied utilities or tools from manufacturer, third-party, or in-house support teams) checked for malicious code (e.g., using antivirus or antimalware scans) before the media are used on organizational systems [a]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Check diagnostic and test media for malicious code before use.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You have recently been experiencing performance issues on one of your servers. After troubleshooting for much of the morning , the vendor has asked to install a utility that will collect more data from the server. The file is stored on the vendor’s FTP server. The support technician gives you the FTP site so you can anonymously download the utility file. You also ask him for a hash of the utility file. As you download the file to your local computer , you realize it is compressed. You unzip the file and perform a manual antivirus scan, which reports no issues [a]. To verify the utility file has not been altered, you run an application to see that the hash from the vendor matches.

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): System maintenance policy; procedures addressing system maintenance tools; system maintenance tools and associated documentation; maintenance records; system security plan; other relevant documents or records

Common mistakes

Trusting a technician's maintenance media without examining it.

Track this in a workspace

The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Source: DoD CIO · https://dodcio.defense.gov/CMMC/