AU.L2-3.3.7
Authoritative Time Source
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- ainternal system clocks are used to generate time stamps for audit records;
- ban authoritative source with which to compare and synchronize internal system clocks is specified; and
- cinternal system clocks used to generate time stamps for audit records are compared to and synchronized with the specified authoritative time source.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Log time stamps only line up across systems if every clock agrees. Use each system's internal clock for audit time stamps, name one authoritative time source (for example NIST's internet time servers, reached through your domain controller or firewall), and configure every system to synchronize with it on a regular schedule. Record time in UTC or with a clear time zone offset.
The minimum for a small organization · Expert CMMC's reading, not official text
Audit records get their time stamps from the system clocks [a]; name the authoritative time source [b]; and compare and synchronize each clock that stamps audit records with it [c]. Point the domain or each device at one reliable time source and check the offset; the guide asks whether clocks map to UTC and are resynchronized on a defined frequency and when they drift more than one second.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeTechnicalName the authoritative time source, and set every system that writes audit records to take its time stamps from its own clock and to compare and synchronize that clock with the named source.[a][b][c]
You can tell it worked when sample workstations, servers and network devices report the named source and an offset within one second, the threshold the guide's assessment considerations give (L2 guide p.94).
SourceCMMC Assessment Guide Level 2 v2.13objectives [a], [b] and [c], p.93Quoted words
- “internal system clocks are used to generate time stamps for audit records”
- “an authoritative source with which to compare and synchronize internal system clocks is specified”
- “internal system clocks used to generate time stamps for audit records are compared to and synchronized with the specified authoritative time source”
- 2Recommended wayTechnicalFor objective [c], synchronize the clocks on a defined frequency: the guide's assessment considerations ask whether the system synchronizes internal system clocks on a defined frequency (L2 guide p.94).[a][b][c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.94 AU.L2-3.3.7
- 3Recommended wayPolicySpecify the authoritative time source in the SSP or configuration standard: for example time.nist.gov (or another stratum-1 government or provider source), with internal hierarchy such as firewall or domain controller syncing to it and all other devices syncing to that internal source. Cloud services (Microsoft 365, Google Workspace) use the provider's synchronized time.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- 4Recommended wayTechnicalConfirm audit records use the system clock and include time zone or UTC offset: Windows event logs and most SIEMs store UTC; set network devices to log with time zone and include the time stamp in syslog messages.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- 5Recommended wayTechnicalConfigure synchronization: in an Active Directory domain the PDC emulator syncs to the specified source and members follow the domain hierarchy; for cloud-joined Windows devices set the NTP server through Intune or Group Policy; set NTP on firewalls, switches, printers and servers; use chrony or systemd-timesyncd on Linux and the time server setting on macOS.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- 6Recommended wayTechnicalMonitor drift: check with 'w32tm /query /status' or 'chronyc tracking', alert in RMM or SIEM when a device's offset exceeds a threshold (assessment guidance cites about 1 second), and investigate devices that cannot reach the time source.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
Notes on 4 products for this practice: why each matters here, what it assumes and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- Firewalls and switches left with no NTP setting, so their logs drift minutes or hours.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- Each device syncing to a different public pool server with no documented authoritative source.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- Virtual machines syncing to the hypervisor host clock while the host itself is not synchronized.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
- Logs from network devices stored in local time with no time zone, making correlation error-prone.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: AU.L2-3.3.1, AU.L2-3.3.5, CM.L2-3.4.2
Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.3.7SP 800-171 Rev 3
03.03.07SP 800-53 Rev 5
AU-8DSSC-45(1)DHow these were reachedHide how these were reached
- AU-8 · Time Stamps
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AU-8 → 800-53 Rev 5 AU-8
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.03.07 → 800-53 Rev 5 AU-8
- SC-45(1) · System Time Synchronization | Synchronization with Authoritative Time Source
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AU-8 (1) → 800-53 Rev 5 AU-8(1) → 800-53 Rev 5 SC-45(1)
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (8 links from 6 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- AU.L2-3.3.7 → 3.3.7“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
Trace notes
Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.
About this practice
Expert CMMC note
800-171 Rev 3 03.03.07 no longer requires synchronizing clocks with an authoritative source (AU-8(1) moved to SC-45(1), outside the 800-53B moderate baseline). CMMC AU.L2-3.3.7 still requires it.
Relies on: NIST SP 800-171 Rev 2, pp.32-33 3.3.7; NIST SP 800-171 Rev 3, pp.35-36 03.03.07; NIST SP 800-171 Rev 3, p.103 Appendix C: Tables 3 to 22 apply to the controls in the SP 800-53 moderate baseline; NIST SP 800-171 Rev 3, pp.113-114 Appendix C, Table 20 (no SC-45 row); NIST SP 800-171 Rev 3, p.119 Appendix E, Change Log: the SP 800-53B moderate baseline; NIST SP 800-53 Rev 5 (OSCAL, release 5.2.0), control AU-08(01); CMMC Assessment Guide Level 2 v2.13, p.93 AU.L2-3.3.7; 32 CFR Part 170, 32 CFR 170.14(c)(3)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Synchronize system clocks with an authoritative time source.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You are setting up several new computers on your company’s network, which contains CUI. You update the time settings on each machine to use the same authoritative time server on the internet [b,c]. When you review audit logs, all your machines will have synchronized time, which aids in any potential security investigations.
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Audit and accountability policy; procedures addressing time stamp generation; system design documentation; system security plan; system configuration settings and associ ated documentation; system audit logs and records; other relevant documents or records
Common mistakes
Allowing inconsistent timestamps that prevent reliable event correlation.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/