AU.L2-3.3.7

Authoritative Time Source

Requirement

Provide a system capability that compares and synchronizes internal system clocks with an authoritative source to generate time stamps for audit records.

Assessment objectives

An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.

Determine if:

  1. ainternal system clocks are used to generate time stamps for audit records;
  2. ban authoritative source with which to compare and synchronize internal system clocks is specified; and
  3. cinternal system clocks used to generate time stamps for audit records are compared to and synchronized with the specified authoritative time source.

From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.

How to implement

Log time stamps only line up across systems if every clock agrees. Use each system's internal clock for audit time stamps, name one authoritative time source (for example NIST's internet time servers, reached through your domain controller or firewall), and configure every system to synchronize with it on a regular schedule. Record time in UTC or with a clear time zone offset.

The minimum for a small organization · Expert CMMC's reading, not official text

Audit records get their time stamps from the system clocks [a]; name the authoritative time source [b]; and compare and synchronize each clock that stamps audit records with it [c]. Point the domain or each device at one reliable time source and check the offset; the guide asks whether clocks map to UTC and are resynchronized on a defined frequency and when they drift more than one second.

Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7

Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.

  1. 1
    Required outcomeTechnicalName the authoritative time source, and set every system that writes audit records to take its time stamps from its own clock and to compare and synchronize that clock with the named source.[a][b][c]

    You can tell it worked when sample workstations, servers and network devices report the named source and an offset within one second, the threshold the guide's assessment considerations give (L2 guide p.94).

    SourceCMMC Assessment Guide Level 2 v2.13objectives [a], [b] and [c], p.93
    Quoted words
    • “internal system clocks are used to generate time stamps for audit records”
    • “an authoritative source with which to compare and synchronize internal system clocks is specified”
    • “internal system clocks used to generate time stamps for audit records are compared to and synchronized with the specified authoritative time source”
  2. 2
    Recommended wayTechnicalFor objective [c], synchronize the clocks on a defined frequency: the guide's assessment considerations ask whether the system synchronizes internal system clocks on a defined frequency (L2 guide p.94).[a][b][c]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.94 AU.L2-3.3.7
  3. 3
    Recommended wayPolicySpecify the authoritative time source in the SSP or configuration standard: for example time.nist.gov (or another stratum-1 government or provider source), with internal hierarchy such as firewall or domain controller syncing to it and all other devices syncing to that internal source. Cloud services (Microsoft 365, Google Workspace) use the provider's synchronized time.[b]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
  4. 4
    Recommended wayTechnicalConfirm audit records use the system clock and include time zone or UTC offset: Windows event logs and most SIEMs store UTC; set network devices to log with time zone and include the time stamp in syslog messages.[a]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
  5. 5
    Recommended wayTechnicalConfigure synchronization: in an Active Directory domain the PDC emulator syncs to the specified source and members follow the domain hierarchy; for cloud-joined Windows devices set the NTP server through Intune or Group Policy; set NTP on firewalls, switches, printers and servers; use chrony or systemd-timesyncd on Linux and the time server setting on macOS.[c]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7
  6. 6
    Recommended wayTechnicalMonitor drift: check with 'w32tm /query /status' or 'chronyc tracking', alert in RMM or SIEM when a device's offset exceeds a threshold (assessment guidance cites about 1 second), and investigate devices that cannot reach the time source.[c]
    Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.93 AU.L2-3.3.7

Evidence to collect

Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.

A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.

Time source statement in SSP or configuration standard[b]

Time synchronization configuration[c]

Synchronization status output[a][c]

The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.

Free with an account. Create a free account or sign in.

How assessors check

What an assessor examines, asks and tests: 3 notes.

Free with an account. Create a free account or sign in.

Tools and products

Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.

Windows Time service (w32time)Time synchronizationFree
NIST Internet Time ServiceAuthoritative time sourceFree
chronyLinux NTP client and serverFree
GPS-disciplined NTP appliance (for example Meinberg or Microchip SyncServer)On-premises stratum-1 time sourcePaid

Notes on 4 products for this practice: why each matters here, what it assumes and what stays yours.

Free with an account. Create a free account or sign in.

Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.

Common pitfalls

Platform notes

  • Microsoft 365 (GCC / GCC High)
  • Google Workspace
  • On-premises or MSP-managed

Notes for 3 platforms.

Free with an account. Create a free account or sign in.

Related practices: AU.L2-3.3.1, AU.L2-3.3.5, CM.L2-3.4.2

Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.

The NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.

NIST SP 800-171 Rev 2

3.3.7

SP 800-171 Rev 3

03.03.07

SP 800-53 Rev 4

AU-8AU-8 (1)

SP 800-53 Rev 5

AU-8DSSC-45(1)D
How these were reached
  • AU-8 · Time Stamps
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AU-8 → 800-53 Rev 5 AU-8
    • S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.03.07 → 800-53 Rev 5 AU-8
  • SC-45(1) · System Time Synchronization | Synchronization with Authoritative Time Source
    • D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AU-8 (1) → 800-53 Rev 5 AU-8(1) → 800-53 Rev 5 SC-45(1)

Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.

Where each link comes from (8 links from 6 official documents)

32 CFR Part 170 Office of the Federal Register / GPO

  • AU.L2-3.3.7 → 3.3.7“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)

NIST SP 800-171 Rev 2 → Rev 3 change analysis NIST

  • 3.3.7 → 03.03.07“Significant Change”sheet "Change Analysis 800-171 R2-R3" row 33

NIST SP 800-171 Rev 2 NIST

NIST SP 800-53 Rev 4 → Rev 5 comparison NIST

  • AU-8 → AU-8“Changes control text”sheet "Rev4 Rev5 Compared" row 199
  • AU-8 (1) → AU-8(1)“Withdrawn”sheet "Rev4 Rev5 Compared" row 200

NIST SP 800-171 Rev 3 (OSCAL) NIST

  • 03.03.07 → AU-8“Source control”control 03.03.07 link rel=reference (AU-08)

NIST SP 800-53 Rev 5 (OSCAL, release 5.2.0) NIST

Trace notes

Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.

About this practice

Further discussion

Each system must synchronize its time with a central time server to ensure that all systems are recording audit logs using the same time source. Reviewing audit logs from multiple systems can be a difficult task if time is not synchronized. Systems can be synchronized to a network device or directory service or configured manually. Example You are setting up several new computers on your company’s network, which contains CUI. You update the time settings on each machine to use the same authoritative time server on the internet [b,c]. When you review audit logs, all your machines will have synchronized time, which aids in any potential security investigations. Potential Assessment Considerations • Can the records’ time stamps map to Coordinated Universal Time (UTC), compare system clocks with authoritative Network Time Protocol (NTP) servers, and synchronize system clocks when the time difference is greater than 1 second [c]? • Does the system synchronize internal system clocks on a defined frequency [c]?

Practice guide notes

Implementation guidance

Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.

In plain language

Synchronize system clocks with an authoritative time source.

Implementation example

Example from the source assessment guide (not a mandatory implementation): You are setting up several new computers on your company’s network, which contains CUI. You update the time settings on each machine to use the same authoritative time server on the internet [b,c]. When you review audit logs, all your machines will have synchronized time, which aids in any potential security investigations.

Evidence examples

Examples suggested by the source guide (not an exhaustive or mandatory checklist): Audit and accountability policy; procedures addressing time stamp generation; system design documentation; system security plan; system configuration settings and associ ated documentation; system audit logs and records; other relevant documents or records

Common mistakes

Allowing inconsistent timestamps that prevent reliable event correlation.