AC.L2-3.1.3
Control CUI Flow
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- ainformation flow control policies are defined;
- bmethods and enforcement mechanisms for controlling the flow of CUI are defined;
- cdesignated sources and destinations (e.g., networks, individuals, and devices) for CUI within the system and between interconnected systems are identified;
- dauthorizations for controlling the flow of CUI are defined; and
- eapproved authorizations for controlling the flow of CUI are enforced.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Decide where CUI is allowed to flow (which systems, people, networks and destinations) and make the systems enforce it. For a small contractor this is usually: CUI lives only in the enclave; it leaves only by approved encrypted channels to approved recipients; data-loss-prevention rules catch mistakes; and the firewall segments the enclave from the rest of the office.
The minimum for a small organization · Expert CMMC's reading, not official text
Decide where CUI may go and make your systems keep it there. At minimum: a written rule naming where CUI is stored and how it may be sent [a], the means that enforce it [b], a simple diagram or list of the places, people and systems CUI moves between [c], which of those flows are allowed and who approves a new one [d], and those means actually in place, such as sharing limited to approved domains and a firewall that keeps CUI systems apart [e]. Settings in the email, file-sharing and firewall you already run are usually where these flows are enforced.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomePolicyDefine information flow control policies for CUI: where CUI may be stored, processed and sent, and where it may not.[a]
- 2Required outcomePolicyDefine the methods and enforcement mechanisms that control the flow of CUI, for example sharing restrictions, encryption for anything sent outside, network segmentation and data loss prevention.[b]
- 3Required outcomeProcessIdentify the designated sources and destinations of CUI, inside the system and between connected systems: the networks, people, devices and outside parties CUI comes from and goes to.[c]
- 4Required outcomeProcessDefine the authorizations for each flow of CUI: which source may send CUI to which destination and by which channel (allow or deny rules for each source and destination, the approved recipients and channels), and who approves a new one.[d]
You can tell it worked when the list or rule set says, for each designated source and destination, whether CUI may flow between them.
- 5Required outcomeTechnicalEnforce the approved flows: the mechanisms are set so CUI moves only between the designated sources and destinations, through approved channels.[e]
You can tell it worked when an attempt to send or share CUI to an unapproved destination is blocked or forced through the approved channel.
- 6Recommended wayPolicyWrite a short information flow policy: CUI is stored only in the named locations of the CUI environment; it is sent only to approved recipients (the customer, primes, approved subcontractors) through approved channels (encrypted email, the customer's portal, an approved file-transfer service); printing and removable media are controlled; personal email and consumer file sharing are not used for CUI.[a][d]
- 7Recommended wayProcessDraw a data-flow diagram showing where CUI comes from (a customer portal, email from the prime), where it is kept (engineering share, ERP) and where it goes (printer, subcontractors). Keep it in the SSP; assessors ask for it early.[c]
- 8
- 9
- 10
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
CUI data-flow diagram[c]
Approved recipient / channel list[d]
The detail for 5 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
29 dated vendor facts and notes on 5 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- A policy with no enforcement: objective [e] asks that the approved flows are enforced, whether by firewall rules, sharing restrictions, a proxy or data loss prevention. A written rule alone does not do it, but data loss prevention is one way, not a requirement.
- Diagrams that stop at the firewall and omit email, portals and subcontractors.
- DLP in audit-only mode forever because nobody tuned the false positives.
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: AC.L2-3.1.20, AC.L2-3.1.21, SC.L2-3.13.1, SC.L2-3.13.8, MP.L2-3.8.7
Editorial implementation guidance published November 14, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.1.3SP 800-171 Rev 3
03.01.03SP 800-53 Rev 4
AC-4SP 800-53 Rev 5
AC-4DSHow these were reachedHide how these were reached
- AC-4 · Information Flow Enforcement
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-4 → 800-53 Rev 5 AC-4
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.03 → 800-53 Rev 5 AC-4NIST: 03.01.03 also: 3.13.3 addressed by; SP 800-172 (Feb 2021) 3.1.3e addressed by (SP 800-171 Rev 3)
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (5 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- AC.L2-3.1.3 → 3.1.3“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Define where controlled information may flow and enforce those boundaries.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You configure a proxy device on your company ’s network. CUI is stored within this environment. Your goal is to better mask and protect the devices inside the network while enforcing information flow policies. After the device is configured, information does not flow directly from the internal network to the internet. The proxy device intercepts the traffic and analyzes it to determine if the traffic conforms to organization information flow control policies. If it does, the device allows the information to pass to its destination [b]. The proxy blocks traffic that does not meet policy requirements [e]. Example 2 As a subcontractor on a DoD contract, your organization sometimes needs to transmit CUI to the prime contractor. You create a policy document that specifies who is allowed to transmit CUI and that such transmission requires manager approval [a,c,d]. The policy instructs users to encrypt any CUI transmitted via email or to use a designated secure file sharing utility [b,d]. The policy states that users who do not follow appropriate procedures may be subject to disciplinary action [e].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Access control policy; information flow control policies; procedures addressing information flow enforcement; system security plan; system design documentation; system configuration settings and associated documentation; list of information flow authorizations; system baseline configuration; system audit logs and records; other relevant documents or records
Common mistakes
Documenting approved data flows without technical enforcement between systems or organizations.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/