AC.L2-3.1.21
Portable Storage Use
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- athe use of portable storage devices containing CUI on external systems is identified and documented;
- blimits on the use of portable storage devices containing CUI on external systems are defined; and
- cthe use of portable storage devices containing CUI on external systems is limited as defined.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
Portable storage (USB drives, external disks, SD cards) holding CUI must not be plugged into systems you do not control, such as a customer's kiosk, a hotel business-center PC or a subcontractor's laptop, unless you have explicitly allowed it under defined limits. Most small shops choose the simplest limit: company-issued, hardware-encrypted drives only, used only on company devices, with exceptions approved in writing.
The minimum for a small organization · Expert CMMC's reading, not official text
Decide whether portable storage with CUI may be used on computers you do not control, and limit it to that. At minimum: write down where it happens today, such as field laptops at a customer site [a]; set the limits, for example company-issued encrypted drives only and only with approval [b]; and keep to them [c]. Many small companies choose no use on outside systems at all, with an approved electronic transfer instead.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessIdentify and document where portable storage devices containing CUI are used on external systems.[a]SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.69
Quoted words
- “the use of portable storage devices containing CUI on external systems is identified and documented”
- 2Recommended wayProcessFor objective [a], count as external both the systems you do not control and, from the point of view of a given system, your own systems outside it. The guide's discussion says external typically refers to systems outside the organization's direct supervision and authority, but that this is not always the case: from the perspective of a given system, other systems within the organization may be considered external (L2 guide pp.69-70).[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.69 AC.L2-3.1.21andCMMC Assessment Guide Level 2 v2.13p.70 AC.L2-3.1.21
- 3Required outcomePolicyDefine the limits on the use of portable storage devices containing CUI on external systems.[b]SourceCMMC Assessment Guide Level 2 v2.13objective [b], p.69
Quoted words
- “limits on the use of portable storage devices containing CUI on external systems are defined”
- 4Recommended wayPolicyFor objective [b], say which devices may be used, on which external systems, and with whose approval. The guide's further discussion describes identifying the portable storage devices that may be used on external systems and the external systems on which they may be used, and its assessment considerations give management approval, authorized personnel only and encrypted drives as examples of limits (L2 guide p.70).[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.70 AC.L2-3.1.21
- 5Required outcomeTechnicalLimit the use of portable storage containing CUI on external systems as defined.[c]
You can tell it worked when the drives used on outside systems, and the systems they were used on, stay within the defined limits, whether those limits are kept by written policy or by drives that work only on systems they can authenticate to.
SourceCMMC Assessment Guide Level 2 v2.13objective [c], p.69Quoted words
- “the use of portable storage devices containing CUI on external systems is limited as defined”
- 6Recommended wayProcessCheck real cases: field service laptops at customer sites, shop-floor machine controllers that are not yours, print shops and subcontractors.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.69 AC.L2-3.1.21
- 7Recommended wayPolicyCommon limits: company-issued encrypted drives only; never on public or personal computers; use on a customer's or subcontractor's system only with written approval, with the drive wiped on return; an approved electronic transfer preferred.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.69 AC.L2-3.1.21
- 8Recommended wayTechnicalEnforce what you can on your own devices: allow only approved encrypted drives through device control and log USB use. Hardware-encrypted drives keep the data unreadable on an unauthorized machine.[c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.69 AC.L2-3.1.21
- 9Recommended wayProcessKeep a register of issued drives (serial number, holder, purpose) and approved exceptions, review it on a schedule you set, and sanitize drives when they come back (MP.L2-3.8.3).[a][c]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.69 AC.L2-3.1.21
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Portable storage use inventory[a]
Issued drive register and exception approvals[c]
The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
18 dated vendor facts and notes on 5 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- Declaring 'we do not use USB' while CNC programs with CUI move to machine controllers on thumb drives daily.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.70 AC.L2-3.1.21
- Unencrypted drives handed to subcontractors with no record.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.70 AC.L2-3.1.21
- Device control turned off because it blocked a scanner or dongle; use allow-lists instead.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.70 AC.L2-3.1.21
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: AC.L2-3.1.20, MP.L2-3.8.6, MP.L2-3.8.7, MP.L2-3.8.8, MP.L2-3.8.3
Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.1.21SP 800-171 Rev 3
03.01.2003.01.21 withdrawn; incorporated intoSP 800-53 Rev 4
AC-20 (2)SP 800-53 Rev 5
AC-20SAC-20(1)SAC-20(2)DSHow these were reachedHide how these were reached
- AC-20 · Use of External Systems
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20
- AC-20(1) · Use of External Systems | Limits on Authorized Use
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(1)
- AC-20(2) · Use of External Systems | Portable Storage Devices — Restricted Use
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-20 (2) → 800-53 Rev 5 AC-20(2)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.20 → 800-53 Rev 5 AC-20(2)
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (8 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- AC.L2-3.1.21 → 3.1.21“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
NIST SP 800-171 Rev 3 (OSCAL) NIST
- 03.01.21 → 03.01.20“Incorporated into”control 03.01.21 link rel=incorporated_into
- 03.01.20 → AC-20“Source control”control 03.01.20 link rel=reference (AC-20)
- 03.01.20 → AC-20(1)“Source control”control 03.01.20 link rel=reference (AC-20(01))
- 03.01.20 → AC-20(2)“Source control”control 03.01.20 link rel=reference (AC-20(02))
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Limit the use of organizational portable storage devices on external systems.
Implementation example
Example from the source assessment guide (not a mandatory implementation): Your organization, which stores and processes CUI, has a written portable device usage restriction policy. It states that users can only use external storage devices such as thumb dives or external hard disks that belong to the company. When needed for a specific business function, a user checks the device out from IT and returns it to IT when no longer needed [a,b].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Access control policy; procedures addressing the use of external systems; system security plan; system configuration settings and associated documentation; system connection or processing agreements; account management documents; other relevant documents or records
Common mistakes
Allowing company USB media to move freely between approved and unapproved systems.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/