AC.L2-3.1.14
Remote Access Routing
Requirement
Assessment objectives
An assessor checks each lettered objective separately. The letters in brackets elsewhere on this page, such as [a] or [b,c], refer to these.
Determine if:
- amanaged access control points are identified and implemented; and
- bremote access is routed through managed network access control points.
From the CMMC Level 2 Assessment Guide v2.13 · publisher approved 2026-10-31.
How to implement
All remote access must come in through a small number of controlled doors you manage, not through whatever port or service happens to be open. Identify the access points (the firewall's VPN gateway, a zero-trust access service, a remote desktop gateway, the cloud identity provider) and block every other path.
The minimum for a small organization · Expert CMMC's reading, not official text
Remote access comes in only through a few doors you manage. At minimum: name those access points, such as the firewall's VPN, a remote access service or the cloud sign-in, and have them in place [a]; and route all remote access through them, with every other way in closed [b]. A firewall that denies inbound connections except the VPN is the usual small-company answer.
Required outcome: what the requirement or its objectives call for. Recommended way: one common way to get there. Going further: worth doing, more than this practice asks.
- 1Required outcomeProcessIdentify and implement the managed network access control points for remote access, for example the firewall's VPN gateway, a zero-trust access service, a remote desktop gateway and the cloud identity service.[a]SourceCMMC Assessment Guide Level 2 v2.13objective [a], p.53
Quoted words
- “managed access control points are identified and implemented”
- 2Required outcomeTechnicalRoute all remote access through those managed access control points, and close every other path into the systems that hold CUI.[b]
You can tell it worked when an external scan of your public addresses shows only the managed access points open.
SourceCMMC Assessment Guide Level 2 v2.13objective [b], p.53Quoted words
- “remote access is routed through managed network access control points”
- 3Recommended wayProcessShow the access points in the SSP and network diagram, each with an owner and logging.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
- 4Recommended wayTechnicalHarden the access points: multifactor authentication and device checks, FIPS-validated encryption (AC.L2-3.1.13), current firmware, logging to a central collector, and administration only from inside or through a separate admin path.[a]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
- 5Recommended wayTechnicalClose everything else: no inbound Remote Desktop, file sharing, SSH or storage web pages exposed to the internet; UPnP off; no stray port forwards; firewall default-deny inbound. For cloud apps, make the identity service the only door.[b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
- 6Recommended wayProcessCheck on a schedule you set with an external port scan and a review of the firewall's inbound rules, and record the results.[a][b]Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
Evidence to collect
Artifacts that show the practice is implemented and operating. Tags show which assessment objectives each one supports.
A process you started recently is shown honestly by its dated procedure, the first record it produced and the date it began. No evidence row needs more history than the process has existed, and the review periods shown are suggestions unless a guide page or regulation is named beside them.
Network diagram showing managed access points[a]
External port scan results[b]
Access point hardening evidence[a]
The detail for 4 evidence items: how to produce each, how fresh it must be, what it must include and what it does not show.
Free with an account. Create a free account or sign in.
How assessors check
What an assessor examines, asks and tests: 3 notes.
Free with an account. Create a free account or sign in.
Tools and products
Named options a contractor can adopt, with an honest cost tier. The industry standard is listed even when it is expensive, alongside what is free and acceptable for a very small shop.
6 dated vendor facts and notes on 5 products for this practice: what each assumes, what it does not cover and what stays yours.
Free with an account. Create a free account or sign in.
Editorial mentions, not endorsements. Pricing and tiers change; confirm with the vendor and check FedRAMP or GCC High availability where CUI is involved.
Common pitfalls
- A forgotten port forward to a camera system, NAS or legacy server.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
- Several remote tools in use (TeamViewer here, AnyDesk there) that bypass the managed path.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
- ISP router in front of the firewall with its own remote management enabled.Expert CMMC's adviceseeCMMC Assessment Guide Level 2 v2.13p.53 AC.L2-3.1.14
Platform notes
- Microsoft 365 (GCC / GCC High)
- Google Workspace
- On-premises or MSP-managed
Notes for 3 platforms.
Free with an account. Create a free account or sign in.
Related practices: AC.L2-3.1.12, AC.L2-3.1.13, SC.L2-3.13.1, SC.L2-3.13.6, CM.L2-3.4.7
Editorial implementation guidance published November 19, 2026. It is not part of the official requirement and does not replace the assessment guide.
Worked paths
Step-by-step recipes, organised by the job, that support this practice. A recipe supports the objectives shown; it does not by itself meet the practice.
Worked path: Remote access for a small office: FortiGate IPsec VPN with FortiClient and Entra ID sign-in
Supports [a] [b] · The FortiGate is the one managed access point, and remote traffic reaches the office only through it.
From vendor documentation, not run by Expert CMMC
Crosswalk
Full crosswalkThe NIST requirements this practice is built on, what NIST made of each in the newer edition, and the SP 800-53 controls behind them, each from an official NIST or DoD table. Open any one to read it and see every CMMC practice it supports.
NIST SP 800-171 Rev 2
3.1.14SP 800-171 Rev 3
03.01.1203.01.14 withdrawn; incorporated intoSP 800-53 Rev 4
AC-17 (3)SP 800-53 Rev 5
AC-17SAC-17(3)DSAC-17(4)SHow these were reachedHide how these were reached
- AC-17 · Remote Access
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.12 → 800-53 Rev 5 AC-17NIST: 03.01.12 also: 3.1.15 incorporated into; 3.13.7 addressed by
- AC-17(3) · Remote Access | Managed Access Control Points
- D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison · via 800-53 Rev 4 AC-17 (3) → 800-53 Rev 5 AC-17(3)
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.12 → 800-53 Rev 5 AC-17(3)NIST: 03.01.12 also: 3.1.15 incorporated into; 3.13.7 addressed by
- AC-17(4) · Remote Access | Privileged Commands and Access
- S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL) · via 800-171 Rev 3 03.01.12 → 800-53 Rev 5 AC-17(4)NIST: 03.01.12 also: 3.1.15 incorporated into; 3.13.7 addressed by
Rev 5 paths: D SP 800-171 Rev 2 Appendix D → SP 800-53 Rev 4 control → NIST's Rev 4 → Rev 5 comparison; S source control of the SP 800-171 Rev 3 or SP 800-172 Rev 3 requirement (NIST OSCAL); C SP 800-172 (Feb 2021) Appendix C. NIST also names this Rev 3 requirement as the successor of other withdrawn requirements: open “How these were reached” under the Rev 5 controls for which, in NIST's words.
Where each link comes from (8 links from 5 official documents)
32 CFR Part 170 Office of the Federal Register / GPO
- AC.L2-3.1.14 → 3.1.14“Level 2 security requirement”32 CFR 170.14(c)(1) numbering (REQ is the NIST SP 800-171 R2 requirement number) and 170.14(c)(3)
NIST SP 800-171 Rev 3 (OSCAL) NIST
- 03.01.14 → 03.01.12“Incorporated into”control 03.01.14 link rel=incorporated_into
- 03.01.12 → AC-17“Source control”control 03.01.12 link rel=reference (AC-17)
- 03.01.12 → AC-17(3)“Source control”control 03.01.12 link rel=reference (AC-17(03))
- 03.01.12 → AC-17(4)“Source control”control 03.01.12 link rel=reference (AC-17(04))
Trace notes
Notes marked NIST state what the owners' own files say. Notes marked Expert CMMC note are our reading of the links, not official guidance. Neither is a crosswalk link.
About SP 800-171 Rev 3 03.01.12
NIST
NIST's own files disagree on where AC-17 (Remote Access) sits in SP 800-171 Rev 3. NIST SP 800-171 Rev 3, p.104 Appendix C, Table 3: AC-17 Remote Access is tailored CUI under 03.01.02. NIST SP 800-171 Rev 3, p.25 03.01.12 Source Controls: 03.01.12 lists AC-17, AC-17(03), AC-17(04) as its source controls. NIST SP 800-171 Rev 3 (OSCAL), control 03.01.12 link rel=reference (AC-17): 03.01.12 references AC-17. NIST SP 800-171 Rev 3 CUI overlay, sheet "CUI Overlay" (AC-17 block): AC-17 is carried by 03.01.12.
Sources: NIST SP 800-171 Rev 3, p.104 Appendix C, Table 3; NIST SP 800-171 Rev 3, p.25 03.01.12 Source Controls; NIST SP 800-171 Rev 3 (OSCAL), control 03.01.12 link rel=reference (AC-17); NIST SP 800-171 Rev 3 CUI overlay, sheet "CUI Overlay" row 98 (AC-17 block)
Expert CMMC note
The crosswalk follows 03.01.12 for AC-17, where the publication's requirement text, NIST's OSCAL and the CUI overlay agree; the Appendix C table row is the outlier. (Precedence: the publication of record over OSCAL over supplemental workbooks.)
Relies on: NIST SP 800-171 Rev 3, pp.24-25 03.01.12; NIST SP 800-171 Rev 3, p.104 Appendix C, Table 3, AC-17; NIST SP 800-171 Rev 3 (OSCAL), control 03.01.12; NIST SP 800-171 Rev 3 CUI overlay, sheet "CUI Overlay" row 98 (AC-17 block)
Further discussion
Practice guide notes
Implementation guidance
Editorial examples to help you plan. Adapt them to your environment; the official requirement and objectives remain authoritative.
In plain language
Route remote access through managed access-control points.
Implementation example
Example from the source assessment guide (not a mandatory implementation): You manage systems for a company that processes CUI at multiple locations, and several employees at different locations need to connect to the organization’ s networks while working remotely. Because each company location has a direct connection to headquarters, you decide to route all remote access through the headquarters location [a]. All remote traffic is routed through a single location to simplify monitoring [b].
Evidence examples
Examples suggested by the source guide (not an exhaustive or mandatory checklist): Access control policy; procedures addressing re mote access to the system; system security plan; system design documentation; list of all managed network access control points; system configuration settings and associated documentation; system audit logs and records; other relevant documents or records
Common mistakes
Allowing direct remote connections that bypass the managed gateway.
Track this in a workspace
The compliance workspace tracks each objective, its evidence and the tasks to close gaps. It is open to invited contractors while in pilot: request access below.
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Source: DoD CIO · https://dodcio.defense.gov/CMMC/